Controllers for heating boilers and systems: an overview of models and their functionality. TRM132M controller for heating and hot water supply with time control Thermal controller for the heating system

Automation of heating and hot water supply systems is necessary to constantly maintain the specified temperature of the coolant and water without direct human intervention.

Benefits of using an automation system

  • Heating and hot water controllers allow you to regulate temperature regime in the heating circuit according to the heating schedule, which depends on the air temperature or on the temperature of the direct water from the mains;
  • automation for water supply maintains the temperature of hot water supply at a given level;
  • Controllers for heating and DHW systems help maintain the desired temperature of heating and DHW systems and change it in accordance with a given schedule: day / night mode, work / weekends and according to an individual schedule set by the user;
  • The heating controller helps to maintain the temperature regime in the return pipe according to a given schedule in order to avoid fines for exceeding it;
  • The feeding of the heating circuit is automated according to the readings of the pressure sensor in the heating network;
  • An automatic transfer of the heating system between the "Winter / Summer" seasons can be configured, with periodic automatic scrolling of the circulation pumps;
  • Overheating during a thaw is excluded, energy is saved;
  • Reduced pump wear due to optimization of the system operation algorithm;
  • Alarm signals are configured in accordance with the readings of the temperature and pressure sensors in the networks, idling, electrical protection, etc.

Controllers KONTAR for heating and hot water systems

Controllers of heating and hot water supply systems "Kontar" are freely programmable controllers that are united into a single network via the RS485 interface, which makes them convenient for creating an extensive geographically distributed network. To program the controllers, the "Konggraph" design environment is used, in which an algorithm is created in the FBD language, which is easy to master for any engineer who is not a programmer. Programs for visualizing processes in the heating and hot water system allow monitoring parameters in real time, locally or via the Internet.

Installation of heating and hot water controllers reduces energy consumption by 30% by optimizing the operation of the systems according to an individually developed algorithm.

Controllers "Kontar" are suitable for automating projects of any complexity and scale from small structures to multi-storey buildings. To expand the system, you do not need to stop the already running controllers. Heating and hot water systems are also integrated with other building systems: security systems, energy metering, etc.

The following devices are recommended in the Kontar line of programmable controllers for the automation of heat points and heating and water supply systems:

  • Programmable controllers - MC8, MC12,
  • Expansion module (input-output module) - MA8.

Development of projects for automation of heating and hot water systems

For heat points, MZTA offers a library of algorithms. If there are no suitable algorithms in it, then you can develop them yourself. The development of algorithms is carried out in a special CONGRAF environment, and then using the CONSOLE software tool they are loaded into the programmable controller.

STANDARD PROJECTS for automation of heating points

A typical control loop for a substation based on a programmable controller usually includes the following functional controls:

  • sensors: temperature, pressure, unauthorized access (optional);
  • controls for giving commands in manual mode;
  • means for visualizing the operating modes of the object;
  • executive devices:
    • low-power (valve drives);
    • powerful (pumps).
The expediency of using the programmable controller MC8, MC12, or their combination, and / or supplementing with expansion modules MA8 depends on:
  • functional control elements used in the technical solution;
  • features of the heating object:
    • heated area,
    • number of storeys,
    • the spatial configuration of the location of pipelines and radiators in the heating system of the facility;
    • the presence of special zones with special thermal conditions.

Table 1 shows the outputs of programmable controllers, which are used to control actuators in the control loop of the substation.

Table 1 Outputs of programmable controllers for controlling executive devices

Programmable controller Output type Quantity Galvanic isolation from controller circuits Load rating limits
MC8Discrete, "Electronic key" (open collector - MC8-301)8 Not48V, 0.15A (DC)
Discrete, "Electronic key" (optocoupler triac - MC8-302)8 There is48V, 0.8A (AC)
Analog:
  • Power source
  • Voltage source
2 Not0 A - 0.02 A
1 There is
MC12"Dry contact"8 There isUp to 250 A AC current

Up to 3 A AC current

Analog:
  • Power source
  • Voltage source
4 Not0 A - 0.02 A
RS485 port (Modbus RTU protocol)1 There is
MA8"Electronic key" (optocoupler triac)2 There is36V, 0.1A (AC)
Analog:
  • Power source
  • Voltage source
2 Not0 A - 0.02 A
All outputs of programmable controllers are equipped with built-in spark suppression circuits. This reduces the risks of failure of the output circuits of the controllers, and also reduces the induced noise in the controller if there are no spark suppression circuits in the connected circuit with reactive load, for example, in the relay coil circuit.

Additional components of spark-extinguishing circuits, intended for installation on a pluggable load, are included in the package of the supplied Kontar programmable controllers.

Depending on the features of a particular solution, control signals to actuators can be supplied through:

  • analog output 0 V - 10 V;
  • discrete output:
    • connected directly to the executive device;
    • connected to the power switch, which in turn controls the power device;
  • RS485 port connected to the actuator via Modbus RTU protocol.
Control actions that can be used to create heat point control algorithms:
  • set in the real-time scheduler (built into the programmable controller),
  • signals manual control(built-in or plug-in toggle switches, buttons),
  • logical sensor signals (presence sensor, temperature sensor),
  • analog sensor signals (temperature, pressure),
  • command from the control room,
  • command from the Master controller.

Ports and inputs of programmable controllers that can be used in the heat station control algorithms are shown in Table 2.

Table 2. Ports and inputs of programmable controllers for solving problems of heat station control

Ports / Inputs Programmable controller
MC8MC12MA8
RS232 port (for communication with upper level) / number of ports+/1 + -
USB (for communication with the upper layer) / number of ports+/1 +/1 -
RS485 port / number of ports / presence of galvanic isolation from controller circuits+ / 2 / yes+ / 2 / yes+ / 1 / yes
Limiting maximum value measured parameter at the universal analog input for:
  • active sensors, with a DC output signal
  • up to 50 mAup to 50 mA-
  • active sensors, with a constant voltage output signal
  • up to 10Vup to 10Vup to 2.5 V
  • passive temperature sensors with internal resistance

    / number of inputs

  • 50 Ohm ÷ 10 kOhm; /eight50 Ohm ÷ 10 kOhm; /eight50 Ohm ÷ 10 kOhm; /eight
    Discrete input (optoelectronic pair) / number of inputs / presence of galvanic isolation from controller circuits+ / 4 / yes+ / 4 / yes+ / 4 / yes
    * Manual switch (Button)+/4 +/4 -

    * When the controller is equipped with a built-in (MD8.102) or external (MD8.3) control panel.

    Discrete inputs of programmable controllers and expansion modules are designed to connect sensors with discrete outputs in the form of a key (relay, open collector, optocoupler triac, etc.) to them. This solution makes it possible to simplify the coordination of programmer inputs with most types of sensors that transmit information about the measured parameter in discrete form.

    The discrete inputs are galvanically separated from the circuits of the controllers / expansion modules.

    The measuring function built into the MC8 / MC12 programmable controllers and the MA8 expansion modules allows you to measure the analog signal depending on the type of sensor / signal:

    For the correct connection of the sensor to the analog input of the programmable controller or expander, a configurator is provided at each input in the form contact group on which jumpers are installed. The configurator is located under the cover of the instrument case. The locations and number of installed jumpers are determined by the type of sensor and its electrical characteristics... Jumpers are included in the scope of delivery.

    Heating and hot water management

    Depending on the scale of the task of automating the control of a heating station, the following can be implemented:

    • Local control of the substation in configurations:
      • Standalone controller (based on MC8 or MC12).
      • Controller network: Master (MC8 or MC12) - Slave (MC12; MC8, MA8).
    • Local or remote dispatching lighting control in configurations:
      • Single controller (MC8 or MC12)
      • Controller network: Master (MC8 or MC12) - Slave (MC12; MC8, MA8)

    To organize stationary local control of heating and hot water systems, special control panels equipped with indicators, control buttons and a liquid crystal display can be used:

    • MD8.102 - built-in, is installed on the case of the MC8 / MC12 programmable controller.
    • MD8.3 - portable, usually installed on the door of the automation cabinet

    Most convenient organization local control of heating and hot water systems can be implemented on the basis of an external operator panel. We recommend external WEINTEK consoles for installation.

    If adjustments to the algorithms are rarely made, and the maintenance specialists are few in number, then the use of external control panels can be completely abandoned. Their role can be played by a wearable laptop, tablet or smartphone connected to the controller directly at the location of the substation via an access point or via a wired interface (USB, Ethernet, RS232). There are special submodules to provide this possibility.

    Dispatching, or remote access to the object, can be organized both on the basis of wired solutions (Ehternet, Internet), and on the basis of wireless technologies radio communication, for example, via a GSM modem.

    The MC8 / MC12 programmable controllers, in accordance with a predetermined list of critical parameters and events, transfer the corresponding data to the supervisory system and / or store them in their internal memory.

    www.mzta.ru

    Controllers for heating and hot water systems: application schemes and development trends

    The word "controller" in translation from English means "regulator" or "control device". According to control theory, it is a device that controls and controls engineering systems and generates control signals for them. Regulators monitor changes in parameters in the engineering systems of the facility and react to this change using a set of control algorithms and appropriate settings.

    In Ukraine, 10-15 years ago, such devices were used, for the most part, in heating points and occasionally in boiler houses. Their functions were limited, that is, they were reduced, for example, to control one mixing valve or separate element systems. In this case, the switching on / off of boilers or pumps was carried out manually. And the circuits themselves were chosen for those algorithms of the controller's operation that could not fully cover all systems of a heating point or boiler room. So various parts the systems were controlled by separate controllers - control of heating, hot water supply, pumps, signaling of faults or alarms, etc. All control devices were placed in sufficiently large control cabinets.

    By now, the situation has changed dramatically. Now the specialist has the opportunity to create almost any control scheme in which the controller can be applied. Volume software can be large enough since modern devices allow storing virtually unlimited amounts of information in memory. The speed of data processing has also been significantly increased.

    The so-called "stand alone" controllers are widely used. preprogrammed controllers. These devices are designed to control individual heating points district heating or decentralized systems. V modern models controllers have not one or two control schemes, as before, but 20 or more. And they can simultaneously control boilers on different types fuel, heat pumps, solar systems, hot water boilers, storage tanks and etc.

    Such devices are supplied to the Ukrainian market by various companies, for example, Danfoss (Denmark), Kromschröder (Germany), Honeywell (USA).

    The required boiler temperature is calculated by the controller based on the heat demand from the controlled heating and DHW circuits. Each device can work independently or in local network, in which there can be several controllers at the same time. All parameters, as well as time programs, are preset for each control circuit and can be individually adapted to the heating system and the user's requirements.

    For example, Smile (Honeywell) controllers (Fig. 1) contain about 20 programs that allow them to be used for 30–40 circuits. The devices can be used locally (with each single controller controlling one or three heating circuits), as well as combined into one system (up to five devices). The controllers have three free inputs and two free outputs for additional functions management. Variations of heating systems are set at the stage of putting the system into operation.

    Rice. 1. Smile controller

    Changes to the operating parameters allow you to achieve a certain level of flexibility in the control of heating systems. Although these controllers have rigid algorithms of work, they can be adapted to a specific scheme. Let's say the controller controls a mixing circuit consisting of a valve, a pump and two sensors on the supply and return pipelines. When it changes certain parameters responsible for the mixing valve can be connected to the controller circulation pump hot water systems, place temperature sensors in the heat exchanger - and the controller no longer controls the heating system circuit, but completely controls the operation DHW systems... That is, the same output can be used for different circuit components. This flexibility is relevant when reconstructing premises with additional heating circuits, for example, partial replacement of radiator heating with a "warm floor" or expanding the DHW system. In this case, one controller will also control the "warm floor" system, radiator heating, a boiler and a hot water supply system.

    It is possible to connect remote modules with indoor air temperature sensors. The connected modules have a knob for changing settings and a switch for “Economy / Schedule / Comfort” modes, a digital display, and duplicate the controller settings buttons, providing full access and remote control... Individual control of a separate heating circuit from one room is possible. To do this, a wall module must be built into the heating system. suitable model.

    Specifications Smile controllers: power consumption - 5.8 VA, work from a household network alternating current... Protection degree IP 30. Dimensions (W × H × D) - 144 × 96 × 75 mm. The housing is made of anti-static ABS plastic. Maximum length busbars - 100 m. The device is wall-mounted using terminal boxes.

    Modern controllers are suitable both for creating weather-dependent systems for regulating the temperature of the heat carrier flow (for example, radiator, convector), and for systems where it is necessary to maintain a constant temperature of the heat carrier (for example, systems of the "warm floor" type, or for swimming pools) by means of mixing circuits, including heliosystems.

    Using several "stand alone" controllers, it is possible to create a sufficiently large and complex control system, suitable even for large public building.

    In individual construction, controllers allow you to organize systems in which it is possible to use various heat generators, including those using alternative sources energy.

    It is almost impossible to create such systems without controllers. After all, all their components have different algorithms and operating modes. It is advisable to turn on the electric boiler at night, when the electricity tariff is cheaper (with multi-tariff metering). Or use the heat pump at the same time. During the daytime, the solar collectors are switched on, and at peak loads on hot water supply in the morning and in the evening, one cannot do without gas boiler... Accordingly, it is possible to turn off the electric boiler during the daytime. In this case, all heat sources operate on a storage tank, the temperature in which must also be controlled and, in accordance with it, the operation of the entire system must be balanced. At the same time, a work schedule is laid down by time of day and days of the week.

    Combined schemes

    One of the most relevant is the use of gas and electric boilers in one system, or a gas boiler and a solid fuel boiler (the first as the main one, the second as an additional one) (Fig. 2).

    Rice. 2. Scheme with the combined use of electric and gas boilers: AF, WF1, WF2, VF1, RLF1, SF - temperature sensors (outdoor air, boilers, coolant in the supply and return pipelines, DHW storage tank); MK1 - electrically operated three-way mixing valve; Tmax - surface-mounted thermostat; P1, SLP, ZKP - pumps

    Moreover, in the first case, since it is advisable to turn on the electric boiler at night, when the electricity tariff is lower, a timer with a day, weekly schedule and a weekend program is used. In the second case, in the absence of gas, the solid fuel boiler will maintain the operation of the heating and hot water supply systems at the required level. Also, heat sources using various types of fuel make it possible to ensure the reliability of the system under certain other force majeure circumstances.

    In this case, the controller provides control of boilers, limiting the maximum temperature at the outlet from the boilers, stepless (smooth) control of a gas boiler with an optimal load on it. It is possible to organize the control of work taking into account the air temperature in the room and weather correction. Freeze protection functions are available, automatic protection from legionella, as well as priority hot water.

    Connection heat pump allows you to create systems in which alternative energy is the base for heating water in a buffer tank (Fig. 3).

    Rice. 3. Use of a gas boiler, a heat pump and a buffer tank: AF, WF, VF1, KSPF, VE1, SF - temperature sensors for the outside air, boiler, coolant in the supply pipeline, at the inlet and outlet of water from the buffer tank, DHW storage tank; KVLF - water temperature sensor; MK1, VA1 - electrically operated three-way valves; P1 - pump of the mixing circuit of the heating system; VA2 - pump for loading the buffer tank from the heat pump

    At the same time, the automation will ensure control of the water temperature at the outlet of the heat pump and optimization of the equipment operation processes. In this scheme, the base heat source is the heat pump and the gas boiler covers the peak loads of the system. Greater freedom of choice of fuel can be provided by a scheme using a solid fuel boiler and a solar collector (Fig. 4).

    Rice. 4. Diagram using a solid fuel boiler, solar collector and buffer tank: AF, WF1, VF1, VE1, SF, VE2, KSPF, KRLF, KVLF - outside air temperature sensors, boiler, coolant in the supply pipeline, at the water outlet from the buffer tank , DHW storage tank, water at the inlet to the DHW storage tank from the solar collector, at the water inlet to the buffer tank, at the water inlet to solar collector, water in the solar collector; MK1, MK2, U1 - three-way mixing valves with an electric drive (heating system circuit, to maintain the set temperature at the inlet to the solid fuel boiler, a valve between the buffer tank and the solar collector); P1 - pump of the mixing circuit of the heating system

    This ensures the maintenance of the set temperature at the inlet and outlet of the boiler, control of the water temperature in the solar collector, switching the flow of water entering the solar collector from the DHW tank and the buffer tank. Parallel weather-compensated operation with a mixing heating circuit is possible.

    To create large heating systems it is often necessary to connect boilers in a cascade, which is also handled by the controllers (Fig. 5). At the same time, optimal parameters and accounting of the operating hours of each heat generator are ensured.

    Rice. 5. Connection of gas boilers to the cascade: AF, WF1, WF2, VF1, VF2, VF3, SF, RLF1, RLF2 - temperature sensors of the outside air, boiler, heating agent in the supply pipeline, DHW storage tank, water in the return pipeline; MK1, MK2, MK3, R1, R2 - three-way mixing valves with electric drive

    In any case, for specific conditions, you can choose the most appropriate scheme, of which dozens of control device manufacturers offer.

    Perspective - the universal controller

    Currently, there is a tendency towards more sophisticated air-conditioning systems in buildings. Developers of controllers adapt accordingly to this trend.

    These devices already allow you to send data on the operation of systems via mobile communication or via the Internet. For example, in the USA wide use got touchscreen monitors with the ability to integrate with operating systems smartphones like Android. Thus, it is possible to remotely control the operating parameters of climate systems, which can include not only heating, but also ventilation systems, air conditioning, security and fire systems.

    Insofar as different manufacturers protected their products with various data transfer protocols, now there are controllers that allow using all existing protocols (for example, CentraLine (Honeywell)). This is especially true when regulators are installed at modernized facilities.

    However, with the increasing complexity of systems, the question arises of creating a kind of universal controller. This is currently the main perspective and challenge for developers. A single controller, depending on the software embedded in it, can be used to control various engineering systems of a building. This is a kind of small computer, for which it is only necessary to install "software" for specific tasks and program it directly for a specific object.

    The complexity of the implementation of freely programmable controllers lies, first of all, in the high cost of the software. In addition, the issue of compliance with the level of training of the user, the availability of qualified service personnel and the exclusion of unauthorized interference in the operation of control devices is relevant.

    aw-therm.com.ua

    Diona - engineering systems »Controllers for heating and hot water systems

    Controllers for heating and hot water systems

    dionabms.ru

    Heating and hot water controllers

    Main Product catalog OWEN Measuring instruments-regulators OWEN OWEN controllers for heating, hot water supply, ventilation, air conditioning Heating and hot water supply controllers

    Sort by:

    are available

    Compare

    are available

    Compare

    The industrial controller OWEN TRM32 is designed to control and regulate temperature in heating and hot water supply circuits.

    are available

    Compare

    The industrial controller OWEN TRM32 is designed to control and regulate temperature in heating and hot water supply circuits.

    are available

    Compare

    are available

    Compare

    The industrial heating and hot water controller OWEN TRM32 is designed to control and regulate the temperature in the heating and hot water supply circuits.

    are available

    Compare

    are available

    Compare

    Controllers of heating and hot water supply systems TRM132M in combination with primary converters, expansion module MP1 and actuators are designed to control and regulate the temperature in heating and hot water circuits, display the measured temperature and operating modes on the built-in indicator and generate control signals for the built-in output elements and output elements of the module MP1.

    Controllers for heating systems from the OWEN company are distinguished by their increased reliability and noise immunity. Such modifications of devices as ТРМ32-Щ4 or ТРМ132М are made in high-impact ABS plastic cases and are able to work effectively even in the harshest industrial conditions. These devices not only regulate the temperature of the heating and DHW circuits, but also protect the system from overtemperature return water returned to the heating plant.

    If you need a reliable and accurate heating control controller, we advise you to pay attention to devices that are manufactured under the OWEN brand. These devices maintain the set temperature level in the system circuits. Also, heating controllers provide for the possibility automatic switching modes, for example, "day-night". The device is characterized by easy programming and intuitive interface.

    In addition, heating controllers perform and protective function... They regulate the temperature of the return water returned to the heating plant. In the event of overheating, the heating controllers lower the readings to normal values, thereby protecting the equipment.

    Why buy a DHW controller on our website?

    Here you will find controllers for heating systems, differing in:

    • the number of inputs-outputs;
    • type of case;
    • interface for data configuration on a PC, etc.

    Each DHW controller presented on the site meets international quality and safety standards, as evidenced by the relevant certificates. In addition, we offer each customer:

    • Low prices... We sell controllers for heating systems at manufacturer's prices. We also offer various discounts and bonuses.
    • Warranty and post-warranty servicing. OvenKomplektAvtomatika specialists have at least 5 years of experience with devices such as controllers for heating systems.
    • Delivery throughout Russia. We will bring your heating control controller by courier service in Moscow and the region. We send devices to the regions by mail, express mail and transport companies.

    Constant monitoring of the operation of the heating system requires a lot of effort and time. However, the emergence of new control devices can significantly simplify this process, and in some cases completely automate it. To do this, you need to install an appropriate controller for heating and boiler control systems.

    Purpose of heating controllers

    The main purpose of this electronic device is to change the parameters of the control devices connected to it to correct their operation. The most simple example an elementary such control element can be considered a system of automatic control protection in gas boilers... But controllers for heating and hot water supply have wide functionality.

    They represent an electronic unit with the ability to control the main elements of the heating system. To do this, it provides the ability to program parameters depending on the data received, from external temperature and pressure sensors. So, a controller for a heating boiler can regulate the operation of the underfloor heating collector or individual thermostats on radiators.

    TO general characteristics electronic control units include the following:

    • System flexibility. You do not need to reprogram the device to connect to heating components. In most cases, manufacturers provide several operating modes for one connection terminal;
    • Choice convenient place to install the control panel. The Honeywell heating controller can be mounted at a distance of up to 100 m from the control element;
    • Control over the functioning of not only heating systems, but also hot water supply;
    • If there is a GPS unit, it is possible to receive data on the state of heating online and send commands to change its parameters.

    The function of connecting the device to a computer is also important. A similar additional module is installed on the Aries heating controller. It is noteworthy that it is not included in the mandatory package.

    The controller can be installed on an old gas boiler. To do this, it is enough to change the heating pad to a new modular type.

    Heating controller selection

    When do you need to install a heating controller? First of all, this device is necessary in case of frequent absences from the house or apartment of residents. By connecting the electronic unit to external sensors temperature (outdoors and indoors) and the boiler control terminals, you can use the built-in software to set up an automatic change in the intensity of the burner.

    How to choose the optimal controllers for heating systems? The easiest option is to consult a specialist. But it is difficult to find one at this time, as this product is relatively new. Therefore, it is recommended that you first independently study the main selection parameters:

    • When comparing a controller for a heating boiler, make sure that the installed equipment has the ability to connect to the control unit. Most often the boiler is characterized by one-stage or two-stage external control. This only applies to gas models- agreement with solid fuel is impossible;
    • The number of components to manage. For a Honeywell heating controller, this value can reach 15, depending on the specific model;
    • The presence of a GPS unit. As mentioned above - this function makes it possible to remotely control the heating;
    • Frequency of software updates. The modern controller of heating and hot water supply systems TRM 32 can be connected directly to the computer. You can always find the latest software version on the manufacturer's website.

    An additional function is to regulate the operation of the components according to the set heating schedule. This possibility is provided in the Aries heating controller. You should also pay attention to the accuracy of measurements. In professional models, this indicator should not exceed ± 0.01 of the scale.

    Heating controllers are rarely repaired. But it is still recommended to choose a manufacturer that has service centers in the region of residence.

    Overview of popular controller models

    Having decided on the required parameters of controllers for heating and hot water supply, you can begin to analyze the offered products. Despite the large assortment, the market is oversaturated with low-quality models. Their actual parameters do not correspond to the declared ones, which subsequently leads to incorrect operation of the heating. Let's look at some really popular and reliable examples of heating controllers.

    Honeywell

    Among the entire product range of the company special place takes the Smile SDC7-21N model. In addition to the affordable price, it is characterized by optimal functionality, which is important for controllers of heating systems.

    It is important for the consumer to know the characteristics of the electronic device. It should be noted right away that for optimal operation of the Honeywell controller in the heating system, you will need to purchase additional modules - terminal blocks for connecting system components, a set of temperature sensors, a 3-way mixing valve and actuator. After assembling the controller, it will be possible to control heating and hot water supply according to the following parameters:

    • Possibility of regulating the operation of the boiler burner with two-stage control;
    • Simultaneous control of 2 cascade boilers. But for this you will need to install an additional temperature sensor at the outlet of the second;
    • The controller for the heating system can regulate the direct and mixing circuits depending on the outside and room temperature;
    • DHW pump control;
    • Possibility of setting a 7-day heating control program.

    In the minimum configuration, it will only work as a controller for a heating boiler. But this will not prevent you from purchasing additional modules and upgrading the system over time. The cost of a complete set is about 45 thousand rubles.

    Best Buy full set equipment, since all of its components are guaranteed to work normally when connected to each other.

    Aries TRM 32

    If you need to choose an option at a more affordable price, it is recommended to pay attention to the heating controller Aries TRM 32. This domestic product is in no way inferior to foreign counterparts in its functionality. It is noteworthy that it can be used to control not only heating, but also hot water supply by several parameters.

    You should immediately warn that the controller unit for heating and hot water supply TPM 32 is more massive than a similar Honeywell. Therefore, you need to think about the place of its installation in advance. In addition to it, the manufacturer offers a remote panel.

    As for the functionality, in addition to the standard features, the following features of the controller for heating and hot water supply of this type should be noted:

    • Automatic maintenance of the water temperature in the DHW circuit;
    • By using PID controllers, high accuracy coolant temperature;
    • Built-in heating protection against water reverse movement;
    • Day / night mode. This function is especially relevant for two-tariff electricity meters.

    But the most interesting for the consumer is the cost of the controller for heating Aries. Base model price without additional equipment is 8-10 thousand rubles.

    Is it possible to independently install a controller for heating and boiler control systems? Despite the apparent complexity, the instructions for each model describe in detail to which terminals the heating components should be connected. If you carefully study the technical documentation of the controller and the boiler, you can install the automation yourself.

    Heating and hot water controllers TRM132M in combination with primary converters and actuators are designed to control and regulate the temperature in the heating and hot water circuits, display the measured temperature and operating modes on the built-in indicator and generate control signals for the built-in output elements and output elements of the MP1 module.

    TPM132M controller capabilities

    • Built-in real time clock
    • Automatic tuning PID controllers
    • Automatic selection of modes (heating / reverse / summer)
    • The ability to change the firmware (using the TPM133M flashing kit)

    Functionality ARIES TRM132M

    • Automatic regulation of the temperature in the DHW circuit in accordance with the preset setpoint
    • Automatic temperature control in the heating circuit according to the schedule from T-outside air and T-direct water
    • Development of the return water temperature graph depending on the T-outside air and T-direct water (protection against over and understatement of the return water temperature)
    • Control of the main and standby pump in both circuits
    • Overtemperature protection in the DHW circuit
    • Controlling the refill water pump in the heating circuit
    • Possibility of using a third pump in each circuit (emergency)
    • Generation of control signals for external actuators and devices in the DHW circuit: shut-off and control valve, main and backup pumps, drain valve (optional); alarm devices
    • Generation of control signals for external actuators and devices in the heating circuit: shut-off and control valve, main and standby pumps, make-up pump, alarm devices
    • Diagnostics of emergency situations (breakage of temperature sensors and position sensors, pump malfunction)
    • Setting the values ​​of programmable operating parameters using the built-in control keyboard, as well as from a PC via RS-485 and RS-232 networks
    • Support of exchange protocols: ARIES, Modbus-RTU and Modbus-ASCI

    Comparison of devices for controlling heating and hot water systems





    For heating and domestic hot water systems with 3-position control valves (220 V 50 Hz).

    • Temperature sensors - 50M, 100M, 50P, 100P, Pt100

    For heating and hot water systems with control valves with 3-position (220 V 50 Hz) or analog (0 ... 10 V, 4 ... 20 mA) control.

    • Universal inputs.
    • Valve control of the make-up circuit.

    For single-circuit (one heating system / one DHW system / one "warm floor" circuit) or double-circuit (two CO, or two DHW, or CO and DHW, etc.) systems.

    • For control valves with 3-position (220 V 50 Hz) or analog (0 ... 10 V, 4 ... 20 mA) control.
    • Universal inputs.
    • Circulation pump control.
    • Cold water pump control
    • Refill water pump control
    • "Quick start" for typical systems

    Rice. 1. Smile controller

    Changes to the operating parameters allow you to achieve a certain level of flexibility in the control of heating systems. Although these controllers have rigid algorithms of work, they can be adapted to a specific scheme. Let's say the controller controls a mixing circuit consisting of a valve, a pump and two sensors on the supply and return pipelines. When you change certain parameters responsible for the mixing valve, you can connect a circulation pump of the hot water supply system to the controller, place the temperature sensors in the heat exchanger - and the controller no longer controls the heating system circuit, but completely controls the operation of the DHW system. That is, the same output can be used for different circuit components. This flexibility is relevant when reconstructing premises with additional heating circuits, for example, partial replacement of radiator heating with a "warm floor" or expanding the DHW system. In this case, one controller will also control the "warm floor" system, radiator heating, a boiler and a hot water supply system.

    It is possible to connect remote modules with indoor air temperature sensors. The plug-in modules have a knob for changing settings and a switch for “Economy / Schedule / Comfort” modes, a digital display, and duplicate the controller settings buttons, providing full access and remote control mode. Individual control of a separate heating circuit from one room is possible. To do this, a wall module of a suitable model must be built into the heating system.

    Technical characteristics of Smile controllers: power consumption - 5.8 VA, they operate from a household AC network. Protection degree IP 30. Dimensions (W × H × D) - 144 × 96 × 75 mm. The housing is made of anti-static ABS plastic. The maximum bus length is 100 m. The device is wall-mounted using terminal boxes.

    Modern controllers are suitable both for creating weather-dependent systems for regulating the temperature of the heat carrier flow (for example, radiator, convector), and for systems where it is necessary to maintain a constant temperature of the heat carrier (for example, systems of the "warm floor" type, or for swimming pools) by means of mixing circuits, including heliosystems.

    Using several "stand alone" controllers, it is possible to create a sufficiently large and complex control system, suitable even for a large public building.

    In individual construction, controllers allow you to organize systems in which it is possible to use various heat generators, including those using alternative energy sources.

    It is almost impossible to create such systems without controllers. After all, all their components have different algorithms and operating modes. It is advisable to turn on the electric boiler at night, when the electricity tariff is cheaper (with multi-tariff metering). Or use the heat pump at the same time. In the daytime, the solar collectors are turned on, and at peak loads on the hot water supply in the morning and in the evening, you cannot do without a gas boiler. Accordingly, it is possible to turn off the electric boiler during the daytime. In this case, all heat sources operate on a storage tank, the temperature in which must also be controlled and, in accordance with it, the operation of the entire system must be balanced. At the same time, a work schedule is laid down by time of day and days of the week.

    Combined schemes

    One of the most relevant is the use of gas and electric boilers in one system or a gas boiler and a solid fuel boiler (the first as the main one, the second as an additional one) (Fig. 2).

    Rice. 2. Scheme with the combined use of electric and gas boilers:
    AF, WF1, WF2, VF1, RLF1, SF - temperature sensors (outdoor air, boilers, heating agent in the supply and return pipelines, DHW storage tank); MK1 - electrically operated three-way mixing valve; Tmax - surface-mounted thermostat; P1, SLP, ZKP - pumps

    Moreover, in the first case, since it is advisable to turn on the electric boiler at night, when the electricity tariff is lower, a timer with a day, weekly schedule and a weekend program is used. In the second case, in the absence of gas, the solid fuel boiler will maintain the operation of the heating and hot water supply systems at the required level. Also, heat sources using various types of fuel make it possible to ensure the reliability of the system under certain other force majeure circumstances.

    In this case, the controller provides control of boilers, limiting the maximum temperature at the outlet from the boilers, stepless (smooth) control of a gas boiler with an optimal load on it. It is possible to organize the control of work taking into account the air temperature in the room and weather correction. Anti-freeze, automatic anti-legionella and hot water priority functions are available.

    Connecting a heat pump allows you to create systems in which alternative energy is the base for heating water in a buffer tank (Fig. 3).

    Rice. 3. Using a gas boiler, heat pump and buffer tank:
    AF, WF, VF1, KSPF, VE1, SF - sensors for the temperature of the outside air, boiler, coolant in the supply pipeline, at the inlet and outlet of water from the buffer tank, DHW storage tank; KVLF - water temperature sensor; MK1, VA1 - three-way valves with electric drive; P1 - pump of the mixing circuit of the heating system; VA2
    - pump for loading the buffer tank from the heat pump

    At the same time, the automation will ensure control of the water temperature at the outlet of the heat pump and optimization of the equipment operation processes. In this scheme, the base heat source is the heat pump and the gas boiler covers the peak loads of the system. Greater freedom of choice of fuel can be provided by a scheme using a solid fuel boiler and a solar collector (Fig. 4).

    Rice. 4. Scheme using a solid fuel boiler, solar collector and buffer tank:
    AF, WF1, VF1, VE1, SF, VE2, KSPF, KRLF, KVLF - sensors for the temperature of the outside air, boiler, coolant in the supply pipeline, at the outlet of water from the buffer tank, DHW storage tank, water at the inlet to the DHW storage tank from the solar collector, at the water inlet to the buffer tank, at the water inlet to the solar collector, water in the solar collector; MK1, MK2, U1 - three-way mixing valves with an electric drive (heating system circuit, to maintain the set temperature at the inlet to the solid fuel boiler, a valve between the buffer tank and the solar collector); P1 - pump of the mixing circuit of the heating system

    This ensures the maintenance of the set temperature at the inlet and outlet of the boiler, control of the water temperature in the solar collector, switching the flow of water entering the solar collector from the DHW tank and the buffer tank. Parallel weather-compensated operation with a mixing heating circuit is possible.

    To create large heating systems, it is often necessary to connect boilers in a cascade, which is also handled by controllers (Fig. 5). At the same time, optimal parameters and accounting of the operating hours of each heat generator are ensured.

    Rice. 5. Connecting gas boilers to a cascade:
    AF, WF1, WF2, VF1, VF2, VF3, SF, RLF1, RLF2 - temperature sensors for the outside air, boiler, coolant in the supply pipeline, DHW storage tank, water in the return pipeline; MK1, MK2, MK3, R1, R2 - three-way mixing valves with electric drive

    In any case, for specific conditions, you can choose the most appropriate scheme, of which dozens of control device manufacturers offer.

    Perspective is a universal controller

    Currently, there is a tendency towards more sophisticated air-conditioning systems in buildings. Developers of controllers adapt accordingly to this trend.

    These devices already allow you to send data on the operation of systems via mobile communication or via the Internet. For example, in the United States, touchscreen monitors with the ability to integrate with the operating systems of Android smartphones have become widespread. Thus, it is possible to remotely control the operating parameters of climate systems, which can include not only heating, but also ventilation systems, air conditioning, security and fire systems.

    Since different manufacturers protected their products with different data transfer protocols, controllers have now appeared that allow using all existing protocols (for example, CentraLine (Honeywell)). This is especially true when regulators are installed at modernized facilities.

    However, with the increasing complexity of systems, the question arises of creating a kind of universal controller. This is currently the main perspective and challenge for developers. A single controller, depending on the software embedded in it, can be used to control various engineering systems of a building. This is a kind of small computer, for which it is only necessary to install "software" for specific tasks and program it directly for a specific object.

    The complexity of the implementation of freely programmable controllers lies, first of all, in the high cost of the software. In addition, the issue of compliance with the level of training of the user, the availability of qualified service personnel and the exclusion of unauthorized interference in the operation of control devices is relevant.

    More important articles and news in the Telegram channel AW-Therm. Subscribe!