Entering the menu and service settings of the ariston boiler. Operating modes and settings of Ariston boilers Fill the heating system with water

Do you want to equip your home with individual heating? Have you already installed and connected your gas equipment? Great, then it remains to figure out how to turn on the gas boiler. Do you think it's enough to plug the plug into the outlet and select the temperature? No matter how it is. Before doing this, you must deflate and fill the system with water. You will find instructions with the sequence of actions in our article.

Boiler start-up for the first time: start

Initial start-up allows you to assess the condition of the heating system.

Important! In case of problems with self-activation, the service center may refuse to guarantee. Perhaps the best solution would be to see a specialist.

In any case, a specialist should carry out the connection to the gas pipeline. Installation and piping of equipment is carried out strictly according to the scheme. It is important to comply with the room requirements for wall and floor boiler, distance from wall and floor. If all assembly work completed successfully, proceed to the next step.

Filling the system with water

For the liquid to enter the system, you need to open the water valve. It is located at the bottom of the case. More precisely, you can look in the instruction manual for your model "Ariston", "Proterm", "Navien".

Unscrew the valve gradually, the water should not flow abruptly, otherwise an air lock will appear. As a result, heating problems will begin. Observe the pressure gauge while filling. As soon as the values ​​reach 2-2.5 atm, close the tap.

Work with water should be carried out in the warm season, otherwise the liquid will form plugs. If it's freezing outside, warm up the room to 20 degrees.

After installing and filling a double-circuit or single-circuit heating boiler, remove the remaining air in the pipes.

Bleeding air from the system

Automatically turning on equipment may have an air release function. But it is more efficient to carry out the work yourself. If you want the room to maintain a stable temperature, then eliminate the possibility of blockages in the pipeline. This is true for both old and new models.

Start the process with radiators. Open the Mayevsky taps located on them.

Substitute containers first, because water will drain with air. As soon as the whistling and hissing stop, you can close the taps.

Bleeding begins with the battery above the rest.

Before starting the boiler, bleed the air from the pump. Can you do it yourself? It is better to carry out the first bleeding manually, despite the automation. How to proceed:

  • Dismantle the case by unscrewing the screws;

  • Connect the boiler "Visman", "Kiturami", "Aton" or the one that you have at your disposal to the socket;
  • As soon as the device is started, the pump will turn on and you will hear a gurgling sound;
  • Using a slotted screwdriver, unscrew the pump nut;

  • As soon as water flows out, screw the nut back. Repeat the procedure until the gurgling stops.

Track the readings of the pressure gauge. If the pressure drops, add fluid to the circuit.

An important point is the setting of the batteries. The far radiators are turned on to the maximum, and the near ones to the minimum. As soon as a comfortable indicator is reached, proceed to the next stage.

Crimping the circuit

During startup, this step is often ignored by users. But in vain! The procedure allows you to immediately find out how reliable and tight the system is. Judge for yourself: if a leak occurs at the height of the heating season and you are left without heat, the costs can be much higher. All you need is a pressure pump at hand.

Blow out the system with a powerful stream of air. The interval between switching on is 10 minutes. During this time, keep an eye on the pressure gauge. The pressure started to drop? This means that there is a leak that needs to be found and eliminated.

Cleansing by rinsing

So that nothing will interfere with the circulation of water in the future, open all the taps on the radiators. Now serve the liquid at a pressure of 4 bar, first substituting the containers. The stream will clean the pipes from rust and sediment. Then clean the filters from dirt.

How to turn on the gas boiler?

The system is ready, proceed to start up the independent boiler. Can I turn it on without gas? No, you must follow the sequence.

For attachments "Bosch", "Vilant", "Beretta", "Ferroli" (Ferroli), Protherm, Celtic and other models:

  • Plug the device into a power outlet;
  • Unscrew gas valve;
  • Press the "Start" button (depending on the model, there may be a different key. See the instructions);
  • Using the buttons on the control panel "+" or "-" set the required temperature mode;

  • The electronic ignition burner will light up automatically when switching to hot water (DHW) or heating. For piezo ignition, hold the flame control for a few seconds, then press the piezo button.

Important! During the initial start-up, air could accumulate inside the gas line, therefore ignition may be blocked. Press the Restart key to release the lock.

For parapet boilers of the "Aton" type, switching on is carried out in the same way. If there is a remote control, then you can set the mode using the remote control.

How to turn on the floor-standing units "Buderus", "Baxi", "Lemax", "AOGV", "Conord", "Danko", "Siberia" and others:

  • Ventilate the room;
  • Make sure there is a draft in the chimney;
  • Open the appliance door;

  • The control and temperature selector must be in the "Off" position;
  • Open the gas valve;
  • Set the selector to the piezo ignition position;
  • Hold down the selector for 5 seconds, press the piezo button at the same time. The burner should light up;
  • Use the same knob to adjust the temperature values.

Can I leave the boiler on during my absence? If you are leaving home for an extended period of time, simply set the rates to a minimum. Low temperatures and frost will lead to freezing of the entire system and other equipment. Metal pipes can burst under pressure, then you will have to completely change the heating circuit.

The last stage of installation of almost any heating system is its first trial run, debugging and commissioning. By by and large, if boiler equipment is launched for the first time, this work is a priority for service centers. During the first start-up, the service center specialists check that the boiler is connected correctly, debug it and put this equipment under warranty. If you carry out the first launch yourself, then you can not count on the warranty service center. Start-up and debugging of the heating system can also be carried out during the operation of the system - you will not turn to specialists every time. Individual heating owners simply need to know this process. We will study it with you in this master class with step by step photos, in which, together with the website, we will study in detail the questions of how the boiler is started and how the heating system is debugged with our own hands.

Filling the heating system with water

Starting a gas boiler begins with filling the heating system with water. Everything is simple here - modern double-circuit boilers do not require the device of a special unit for making up the system. It is already built into the boiler and equipped with a special tap, which, as a rule, is located at the bottom of the boiler in the immediate vicinity of the cold water connection. We open the make-up tap and slowly fill the system with water.

Starting the boiler - how to fill the system with water

Highly important point in the operation of any boiler equipment is the fluid pressure. To control this parameter of the heating system, almost all boilers are equipped with a pressure gauge. In the process of filling the systems with water, it is necessary to monitor the pressure and after it reaches the level of 1.5-2 atm, the filling of the system will need to be stopped. In principle, the indicator of the working pressure of the boiler may vary depending on the manufacturer and model - therefore, for the exact figure of the working pressure, see the instructions for the boiler.

Do-it-yourself first start of a gas boiler

Removing air pockets in the system

Better to start with batteries. For removing air congestion a Mayevsky crane is usually installed on them. We open it and wait for the water to run. Did you run? We close. Such manipulations must be done with each heating device separately.

How to start a boiler with your own hands photo

After the air from the batteries is removed, the pressure in the system will decrease and the pressure gauge needle will drop. At this stage of work, the solution to the question of how to start the boiler involves re-feeding the system with liquid.

Now, the most difficult thing is that starting gas boilers requires venting air from the circulation pump. To do this, the boiler needs to be disassembled a little. We remove the front cover and look for a cylindrical object with a shiny lid in the middle, which has a slot for a screwdriver. After finding it, we start the boiler into operation - we supply it with electrical power and set the water heating regulators to the operating position.

Air discharge from the circulation pump when starting the boiler photo

Turns on immediately circulation pump- you will hear a faint hum and loud gurgling and many incomprehensible sounds. This is fine. As long as the pump is airy, it will be so. We take a screwdriver and slowly unscrew the lid in the middle of the pump - as soon as water begins to seep out from under it, we twist it back. After two or three such manipulations, the air will come out completely, the incomprehensible sounds will subside, the electric ignition will work and start to work. We check the pressure again and, if necessary, add water to the system.

Basically, that's it. While the system is warming up, you can study the instructions in detail (if, of course, you have not already done so) and start debugging the system, which involves starting the boiler. Everything is simple here - the batteries closest to the boiler must be screwed on, and the distant ones must be started to the full. Such debugging is carried out by means of control valves installed on the supply connection to the heating radiator.

He turned on the ariston bs 24 ff boiler in heating mode, set the coolant temperature to more than 60 degrees and the following began to happen - after the burner turns off, after 5 seconds crackles begin in the boiler, approximately in the upper part in the area of ​​the heat exchanger. What is this malfunction? The boiler has been in operation for 2 years.
Maintenance was carried out, except for cleaning the inside of the heat exchanger from scale and other things! The technician who carried out the maintenance said that there is no need to descale! The device, as it worked 2 years ago, still works unchanged, except for crackling after the burner goes out, but only at coolant temperatures above 60 gr.
Carried out the installation and installation of the wall-mounted boiler Ariston. It works great for heating. The DHW turns on, heats up for about a minute and the flame turns off, the green 40-80 are on, then the green 40-50 error and the yellow chimney "Alert for insufficient water under pressure" blinks. After which the flame appears and heats further, then turns off again.
The Ariston Uno boiler is set to summer mode. I turn on hot water in the tap, the boiler is working normally (heats the water). After disconnecting hot water gas is ignited on the radiator circuit, and the boiler continues to heat water already in the system. After a while, he either stops (it seems as if he "remembers" that he is on summer mode) or try to re-ignite the gas at heating system... But he can't do it.
Most likely, you will have to reflash the program memory.
Installed a gas boiler Ariston Uno 24 MI. At first it worked fine, but about 3 months ago problems started, first with hot water, and then with heating. During ignition, the boiler ignites, but the ignition clicks are heard for 7-10 seconds, and then the protection is activated, the boiler goes out, the red light is on. After pressing the restart button, it lights up and works normally. Previously, it was 1-2 times a day and only when hot water was turned on, but now it is constantly. Tell me what could be the problem?
Clean the flame control electrode with a zero point; it is probably covered with soot. Do not know who is responsible for the control - it will not hurt to clean everything that is in the combustion chamber above the burner. Well, if it doesn't help, then the fee.
What is the reason for the blocking of the Ariston UNO 24 MFFI boiler when the heating is turned on? Moreover, the blocking occurs after about half an hour of operation - when the batteries are fully warmed up. I thought maybe the temperature sensor, but the indicator "says" the ignition.
It is necessary to pay for the repair, it is not necessary to change it.
The boiler Ariston Uno 24 MFFI EE is faulty - the yellow lamp turns off and lights up. How to fix?
Check the operation of the turbine.
Check the pressure switch.
Check the functionality of the email. boards.
The Ariston Uno 24 boiler operates in heating mode and periodically turns off. with extinction of all diodes. When incl. its on a button incl. it starts, for a while it can work for an hour or half an hour and off. It seems to me that the fee.
Recently carried out repairs. Did the following.
1- cleaned the air vent valve. Didn't work completely.
From this, in the heat exchanger, due to the presence of air, the scale turned into some kind of black flakes. (local overheating affected).
2- flushed both heat exchangers. The secondary was 90 percent clogged.
I did the second operation twice. But I think I'll have to repeat it in the spring.
3-flushed the filter on the return line.
It looks like the secondary heat exchanger is clogged with scale, overheats and turns off. Need to rinse!
The gas boiler Egis Plus 24 FF is in operation. The pressure in the heating circuit dropped by 0.5 atm for two weeks. Checked expansion tank, there was zero. Pumped up to 1 atm. Now it began to fall more slowly, the pressure in the expansion tank is normal. For what reason can there be such a drop in pressure in RB? Outwardly, he is whole, the air does not poison. Basically, the pressure in the heating circuit drops after using hot water. At
pumping closed the taps for supply and return. I drained the water from the boiler, it spilled out a little when I pumped it up. Before that, the season worked fine.
If you are sure that it is falling in the heating circuit, then look for a leak in it.
Installed and connected Ariston Egis Plus 24 with an open combustion chamber.
There is a problem, advice is needed:
1. The temperature in the DHW circuit does not depend on the set parameters and is always maximum. Regulated in the heating circuit.
2. Feeling that the boiler does not change the intensity of the flame (in both modes). It lights up at maximum and works like this until it turns off when the maximum temperature is reached. Is it customizable in some way or something more serious?
First you need to look at the gas valve settings.
The boiler generates error 104 during heating operation. The pressure in the expansion vessel is 1 bar. the pressure in the 1.4 bar apparatus does not drop, the bypass is normal, the turbine and everything else is also normal. Everything is clean along the contour. What can the third digit mean in the error? Boiler Ariston Chimney class. And if we have a pressure sensor? I didn't find it.
If the error is only when working on heating, most likely, the malfunction needs to be looked for in the heating system, I would start by checking the CO filters. Most often not, but there were instances with a pressure sensor. Check menu 247 to be correct and set 0 if necessary.
We installed and launched the Ariston Clas System 15 FF wall-mounted boiler. During operation, it gives an error 104. Pressure in the expansion tank 1. The pressure in the boiler 1.5 does not drop. The filter is clean. There is no air in the CO. The heat exchanger is flushed clean. What could be the malfunction? It stops 3-4 times a day. I noticed that when an error occurs, some hiss and a pressure surge from 1.5 to 1 and again to 1.5 becomes and error 104 appears.
Options: board, pump, NTC.
Tell me, must the coolant be drained before air injection?
We drain (bleed through the vent) the coolant until the pressure gauge shows 0. Before that, shut off the CO cocks under the boiler. Then we pump the pressure into the air part of the expansion tank with a pump, checking the pressure with a third-party pressure gauge. We pump up 1.0-1.2 bars. We open the taps. Then we pump it with pressure in CO, control the pressure with a boiler pressure gauge. We pump either through the make-up tap or by third-party
pump at the CO filling point. We pump up to 1.3 -1.5 bar. We check if the air vent is open. We turn on the boiler, and if there is a mode for removing air from the CO, then we drive the device in this mode. We also warm up the CO to the maximum. Air is removed from CO. We go through the heating devices and bleed the air from them through the Mayevsky tap. The pressure will drop slightly. We feed up to the values ​​indicated above. Everything. If everything is correct, then at
heating to maximum temperature, pressure in closed system will not rise more than 0.3 bar.
Malfunction in the operation of the double-circuit boiler ariston egis 24 ff - when hot water is turned on for 20 seconds of operation, the flame goes out and error 109 lights up the plausibility test failure. What is it and how to fix it? First, the burner goes out, and then 109 comes on. DHW temperature is the temperature of the water in the tap? Can I make repairs myself?
Choose one of the options:
1. Error 109 lights up and after that the burner goes out;
2. The burner goes out and then error 109 lights up;
Set the DHW temperature to 50 degrees or less and see if there are any changes.
Tell me, where is the expansion tank on the Egis 24FF gas boiler, and more specifically the pumping valve? And how to properly drain the water from the boiler? To correctly pump up the pressure into the expansion tank.
Located at the back, above the boiler.
- Close the tap of the cold water inlet to the device.
- Open a hot water tap on the mixer at any point of the tap.
- Open the make-up tap.
- Wait until the pointer of the pressure gauge is at zero.
The problem in the operation of the double-circuit boiler Ariston BS II 24 CF. When the heating is turned on, the burner starts up and turns off after a short time, the system does not completely warm up, and the device is already turned off. They called the foreman, he said that the pump was out of order, although when the boiler was turned on, a slight vibration was felt and the supply pipe heats up and the first three radiators too (the remaining three were not possible to check). But
the return line is slightly warm. The boiler does not give out errors. Tell me how you can check the pump's performance?
Turn off the boiler using the button and from the socket; turn off all the taps, drain the water from the device through the drain fitting, cover the board with some kind of waterproof oilcloth on top so that water does not get in, remove the pump and try to turn it by hand - how easily it turns.
1. the return filter is clogged.
2 the filter in the boiler is clogged (the pipe where the pressure gauge comes in).
3 the heat exchanger is clogged.
4. the pump does not reach the operating parameters.
Aegis plus 24 FF boiler is in operation. When I turn on the hot water supply, the device turns off after 30 seconds and displays error 303. Tell me, what could be the damage?
Most likely, you will need to change the board.
The boiler Ariston BS 24 FF was installed, it worked for 4 years without breakdowns. Now there is a problem: You set the temperature, for example, 70, the boiler does not heat up the entire system, although everything was normal before. Only the first 3 batteries are heated, respectively, the return flow cools down, the device turns on for a short time (the sensor on the dial shows a maximum of 40) and the heating is turned off, although the return flow is slightly warm. I don’t know what the problem is, maybe you need to install an additional pump? (The stabilizer is installed, the filter is only from mechanical impurities.).
The filter in the boiler is clogged.
We are going to connect a 15 kW single-circuit wall-mounted gas boiler Ariston. Does it need an expansion tank? How to check the boiler after starting up?
This model already has a standard expansion tank, but its volume is not always enough for work. We need to inspect the heating system. If it is large enough, then it will be necessary to embed an additional tank outside the boiler. Before starting commissioning, fill the heating system with water, including underfloor heating and radiators, and ensure that the chimney is ready.
The Ariston boiler is in operation, which is powered by a liquefied gas cylinder. Recently, it has become scary to turn it on: the volume of the flame soars up high. How can you fix and repair?
It is necessary to see why there is no flame control, and what is out of order - a reducer or a flame regulator, or there is another reason for this phenomenon.
Boiler malfunction Evo class. Suddenly stopped turning on, only the fan works without stopping. Shows errors 201 and 607. Can this be fixed?
Error 201 means a short or open circuit in the hot water circuit temperature sensor circuit. Error 607 is the pressure switch contacts are closed before the fan turns on.
In Egis Plus 24, the heating mode was turned off, only hot water was left. It became impossible to start it: writes "Board failure". How to make repairs yourself?
Measure the potential between zero and ground, there should be nothing. If the voltage is at least 2-3 V, then the boiler will write an error and the potential must be removed. Then you should find out the voltage in the network: at 180-190 V, the board will also fail. If everything is in order, then the problem is in the board itself.
Ariston Genus 24 is connected, the error "flame separation" began to appear. How is this eliminated?
The cauldron is clearly too high pressure gas. The gas valve must be adjusted. There may also be a problem with the air supply to the boiler.
Double-circuit boiler Class 24 has stopped giving hot water, error 103 is displayed. What can you do yourself?
This error code indicates insufficient circulation of the coolant. The water pressure in the DHW circuit should be checked, if it is low, then there may be a leak. If the make-up gives nothing, or gives a short-term effect, you should call a specialist.
When you open the hot water tap, the wall-mounted gas double-circuit boiler Ariston Class 24 turns on, d38 is displayed on the display, and after 2-3 seconds. 5P3 ​​appears and immediately again d38, after 2-3 seconds again 5P3 and immediately again d38. And so the information on the board changes during the first 20-25 seconds. heating water. Then the water heats up without problems and d38 is constantly on the screen. It started after they stopped heating the house, that is, the boiler
works only for heating water. This is the first question. And the second: After closing the hot water tap, error 104 lights up on the display. The boiler starts up only after pressing RESET. What could be the cause of these problems?
There was the same malfunction. We decided to flush the secondary DHW heat exchanger. But you have to flush every six months. The symptoms were one to one. Yet. There is a special device for flushing, it is connected to the input / output of the DHW circuit. If you use it every six months, then such a rinse is sufficient. If the heat exchanger is heavily contaminated with deposits, then it is necessary to remove the heat exchanger, and "soak" in a solution with citric acid(with vinegar).
We installed and started up the clas evo 24 ff boiler. A malfunction has occurred. The boiler does not pump the heating system, the first two radiators are warming up. Heating polypropylene. At the same time, it does not give any errors. What could be the problem? I also want to add that the temperature quickly builds up for about one and a half minutes and the boiler goes out.
There is no circulation of the heating system, there may be a blockage or the transport plugs from the radiators may not be removed, there may be air both in the pump and in the system.
The gas boiler Ariston clas system 24 ff was put into operation. When starting up, the boiler does not always ignite, it is clear that there is a spark, a certain amount of gas flows (I noticed the meter readings), but the flame does not ignite. After 8 seconds, as expected, error 501 is displayed. Sometimes, at the moment of ignition, you can see how a small flame flares up and goes out, sometimes it ignites without problems with a normal flame. I also noticed that the flame on the burner happens
different strengths. I thought that this was due to the temperature of the coolant, but with several switching on and off of the boiler, the flame is different at the same temperature. The boiler was installed what is called "as is", i.e. no parameter adjustments have been made. The only parameter that tried to change this parameter 220 "Smooth ignition" - the factory setting is 47, tried to increase to 80 - did not give a result, returned it back.
I didn't change any other parameters. I also noticed that when the temperature setting is increased to 61 degrees, the device does not turn off, i.e. it gradually reduces the flame as it approaches the temperature and continues to burn in this mode. When the temperature was set to 53 degrees, it heated up and turned off, but then it could not start due to the above problem. Find a specialist for such boilers in our outback
impossible, and the nearest center is 200 km away. Maybe someone faced a similar problem? Please advise what test operations need to be done to identify the malfunction.
It is necessary to slightly increase the minimum gas pressure on the gas. valve. Warming up to the set temperature takes place for min. pressure. DHW control (knob) - to the maximum. The flow must correspond to the maximum (12 l / min). The first measurement (on gas) at the inlet, in statics, then at start-up. If the pressure drops below 14 mbar, do not touch the valve, otherwise you will knock off all factory settings.
Tell me, I have a wall-mounted gas by-pass boiler Ariston Class 28 CF installed. When DHW is turned on, the water temperature does not correspond to the temperature set on the screen. At first I didn’t pay attention to it, but lately the readings are very different, I put 45, and it flows, about 38. How to fix it? Can I carry out repairs myself?
You need to check and Maintenance with full cleaning done.
After switching on the boiler (in heating and hot water mode), the green LEDs 50/60/70 and the yellow LED house light up, the boiler does not ignite. What to do?
This error is the presence of a flame when the gas valve is closed (false flame). The board needs to be repaired.
I have a wall-mounted boiler EGIS II 24 FF connected for three years of operation. During the year, the fan relay failed several times, what is the reason? The fan runs constantly!
Sticky contacts. Perhaps the propeller rotates heavily, because of this, the current through the contacts is too high. Try to put a relay with a high current. (More than it was) the current is indicated on the relay case. Also check the contacts of the fan connector on the board and the contacts on the fan itself - perhaps somewhere the contact is not very good, because of this, the relays do not work for a long time. In boilers of this series, resetting this parameter (protection against
water hammer) is not provided for any of the three modifications of the control board.
The boiler is new. For some reason, the DHW circuit does not work. The heating is working properly. On an attempt to turn on hot water, the boiler only shows the temperature, and is not even going to heat it, it waited about 5 minutes.
The problem is in the 3-way valve. The caliper let the water in - ruined the mechanics of the servomotor. You need to change both.
Installed wall gas boiler BS II 24 CF NG. When DHW is turned on, the yellow lamp (t-40) first comes on, and then it starts to flash. The water heats up normally, the heating works, in general, everything works. Should a light be blinking or some kind of system malfunction. When heating and DHW are on, it is on, not blinking. They told me that it shouldn't be that way, it should just burn. The boiler was installed just now, we are afraid of failures in winter period.
The boiler was installed this spring, there were no problems. Now a rather strange breakdown has occurred - an error 5p3 (flame separation) appears. Moreover, the error appears only if the temperature of the heating circuit is set below 60 degrees (the device tries to start, ignition is heard, the burner icon appears on the panel for a second, then it disappears and an error pops up). If I set it to 60 degrees or more, the problem goes away. What could it be?
This 5P3 error on these boilers may occur due to the pulse power supply installed there. The potential that the ionization electrode sees arises as a result of combustion meets the potential of the boiler itself (which will be more than 5V) if it is not grounded, this error may occur. The technician can check this by disconnecting the ground wire from the main control board and restarting the boiler at your desired temperature. the error should be gone. If this does not happen or your boiler is grounded. Then you need to look at the settings of the gas valve.
The gas boiler Ariston Egis plus 24 FF is in operation. When the hot water tap is opened, cold water starts to flow almost immediately after opening, then hot for 20 seconds, and again cold, again hot for the same approximately 20 seconds, and again cold, and this continues indefinitely. The display of the gas boiler shows err 109, judging by the instructions this is some kind of "plausibility text failure". Can you tell us what this test is than
an error could be caused, and how can I fix the problem?
The boiler needs maintenance.
Tell me about connecting a room thermostat to the boiler. He did everything according to the scheme that came with him. To begin with, I threw off the jumper, the boiler did not start - this is normal! I connected a room thermostat, the device did not start, but when I turned the knob, somewhere more than 23 degrees there was a click in the thermostat, the boiler started to work, but it turns off and on without responding to the thermostat. I tried to throw on the thermostat
terminals, on the contrary, the device turns on up to 23 degrees, when you turn the thermostat knob, a click and the boiler turns off, but in this position it does not respond to the thermostat. Who knows, tell me, maybe I'm doing something wrong!
Probably turns off due to overheating of the coolant above the ordered temperature. Add the boiler temperature.

Double-circuit gas appliances make our life more comfortable and enjoyable. They are quite practical to use, suitable for heating country houses, and small apartments... They are used for heating industrial or warehouse buildings, the area of ​​which is not more than 500 sq.m.

The advantages of Ariston boilers are that, in addition to heating buildings in winter, they heat the water used in everyday life. all year round... It is quite convenient and does not require the installation of additional equipment.

General characteristics of Ariston boilers

The description of Ariston gas units must begin with the characteristics of their main part - the burner. This element is used to burn fuel and to transfer thermal energy to the heating system.

Types of boiler burners:

  • common
  • modulation

The modulating burner is more convenient to use. It provides for automatic power regulation depending on the temperature of the device.

By the type of removal of combustion products, burners are divided into:

Units with a closed burner are safer to use. Combustion products natural gas in this case, do not enter the room. The use of a chimney is not required. A coaxial pipe is simply connected to the device and brought out.

The design of the coaxial pipe provides for the presence of two layers, which ensures the simultaneous removal of waste and the flow of air from the street into the burner.

Equipment with an open burner provides for the mandatory use of a chimney to remove combustion products.

Ariston Gas Appliances Technical Data

  • Ariston boilers are used for heating and heating water, that is, they are double-circuit. Each modification has its own characteristics, but the common thing is the type of fuel - gas.
  • The gas combustion chamber can be either open or closed. In the presence of a chimney, units with an open chamber are used. And in apartments multi-storey buildings where chimneys are not always available, use equipment with closed chamber combustion.
  • Power. This indicator is used to calculate the gas consumption required to heat the room.
  • Compactness. Wall-mounted appliances are used in small, narrow rooms... Floor-standing units used in production or storage areas are heavier and require more installation space.
  • The presence of a control unit. This element is indispensable when the water is turned off, the gas drops sharply. In case of any malfunction, the unit will immediately turn off the device, which will prevent damage. It also helps to save fuel consumption.

Ariston boilers are used for heating and heating water, that is, they are double-circuit

Characteristics of Ariston boiler models

A distinctive feature of Ariston boilers is their high quality... After all, the name of the company is translated from Greek as "the best".

Her products are especially popular with middle-income consumers. Gas boilers this brand is purchased for heating rooms up to 500 sq. The company's products are universal. The transition to liquefied fuel is carried out only by replacing the burner.

Two-circuit wall-mounted gas appliances are practical to use. It is represented by three lines, each with its own modifications.

For all modifications of boilers, the following is common:

  • small size.
  • hot water supply, in the absence of its centralized supply.

Gas boilers of different modifications differ from each other in structure, their common is their low cost and quality performance details.

Basic configuration of units from Ariston:

  • double heat exchanger.
  • electronic control module gas burner.
  • control of carbon monoxide.
  • microclimate support in a building or in a separate apartment.
  • control of water freezing inside the system.

Let's consider in more detail existing species Ariston equipment.

Ariston genus

  • Available with double heat exchanger. All modifications are double-circuit and are mounted on the wall.
  • This model is considered the most functional of all Ariston devices. Has an LCD display, a control panel with buttons. Ariston Genus can be configured to operate autonomously for an entire week.
  • The display shows basic data on the status of the device and a list possible mistakes... The burner is modulating, that is, it is fully electronically controlled. This function increases the comfort of using this model of gas appliance, due to the minimum control by the consumer.

The Ariston Genus line includes the Evo and the more expensive Premium models.

The Evo model is a double-circuit gas appliance with both types of burner: open and closed.

Genus Premium condensing boilers... They are used for heating residential buildings and commercial buildings. Power range from 24 kW to 35 kW.

Ariston clas

  • The device is small.
  • This is a boiler with two circuits and a graceful appearance... The reduced size did not compromise its functionality in any way.
  • Expansion tank 8 l. Hot water heating is fast enough

Existing modifications:

  • Evo is available with open and closed combustion chambers. Power with an open burner - 24 kW, with a closed one - 24 - 28 kW.
  • Premium Evo is a condensing unit. Has extended comfort and freezing functions
  • Premium simple condensing unit.

Ariston egis

  • It is installed mainly in rooms up to 200 sq.
  • The most common model of the Ariston gas appliance in our country. Heats water with a stainless steel heat exchanger, and a copper heat exchanger is used for heating.
  • A compact device, it is economical and can be used in difficult weather conditions. For example, at sharp subzero temperatures.
  • The appliance is equipped with a modulating gas burner, which allows electronic control over the operation of the boiler.

This model is adapted to work in harsh climatic conditions. Normally withstands gas pressure differences. The device is equipped with a collector into which the condensate flows. This ensures operation at temperatures below 50 degrees.

> Cost of Ariston boilers

The average cost of Ariston Genus boilers is 54,000 - 72,000 rubles, Ariston Clas - 25,000 - 34,000 rubles, Ariston Egis - 27,000 - 34,000 rubles

Choosing a gas appliance for heating

Ariston products can be found in catalogs. There are many models of gas appliances. The main mistakes when choosing the wrong unit are made from a lack of information. Therefore, before visiting the store, you should familiarize yourself with the basic tips for choosing a wall-mounted gas appliance.

When choosing a boiler, take into account the following points:

  • The size of the kitchen, as the place where the heating appliance is most often installed. In the store, the choice begins with consideration overall dimensions apparatus and select it individually for your kitchen.
  • Next, they go to the technical data and study the type of water heater in the apparatus. If there are a large number of people in the family, then it is not recommended to purchase a boiler with an instantaneous water heater.
  • In this case, it is more rational to purchase a boiler with a storage tank for hot water and select equipment for the amount of water that you will need for everyday use.
  • Combustion chamber evaluation gas equipment... It can be closed and open. It is recommended to choose a boiler with a closed chamber, due to the fact that it is safer to use. The presence of a chimney is optional, which is important in multi-storey buildings... Enough to buy and bring out a coaxial pipe.

Most common error codes and troubleshooting methods

The most demanded among Ariston boilers are wall models by 24 kW. During the operation of the gas boiler Ariston, malfunctions and malfunctions may occur, like with any other equipment. The list of error codes is given in the instructions in the form of a table. Some of them are a malfunction in the operation of the automatics (cause a protective shutdown of the device) and are eliminated by pressing "Reset", and some signal faults and interference in the operation of the boiler and require intervention (block the operation of the system).

All codes are divided into six groups according to the number of boiler units. The first value denotes the node in which the failure occurred, the rest - the error code, but keep in mind that if the security error is repeated frequently, this indicates a malfunction.

The most common ones are:


Ariston Clas Evo boiler control panel

  • error 501 - lack of ignition. Check if the gas valve is closed, if there is a supply, pay attention to the ionization electrode, it may get wet, dry it with a hairdryer. See if it has bent back, the distance from the electrode to the comb should be 8mm with a tolerance of 1mm, is there a good connection between the electrode and the board;
  • error 607 - sticking of the contacts of the fan control relay, replacing the relay, and sometimes the entire electronic control unit, will help.
  • 101

    Error 101 means overheating, a sensor has been triggered, after cooling down, the boiler starts up. The reason may be the accumulation of scale in the heat exchanger, as a result of which the flow rate decreases and the temperature increases, or interruptions in the operation of the circulation pump. Flush the heat exchanger, adjust or change the pump. Sometimes the reason may lie in the increased gas supply, screw on the valve, if it does not help, you need to adjust the gas valve.

    103,104,105,107

    Error 103, error 104, error 105, error 107 occur when there is a violation of the water circulation in the circuit, its absence or low pressure. This happens when air has accumulated in the system, to remove it in the Ariston Egis Plus 24 boilers, press and hold the mode button for 10 seconds. On boilers Ariston Mathis and Ariston UNO, hold the rezet button for no more than 6 seconds. The pump will run for 5 minutes without igniting, removing air from the system. then check the pressure, the norm is 1-1.2 bar, if necessary, increase.

    Ariston Egis Plus 24 boiler

    108

    Error 108 appears when there is insufficient water pressure in the heating circuit. Why does the pressure drop - the cause may be a leak from heating radiators, you should check the joints in the pipes. During the heating season, it will not be easy to notice a small leak, since a small leak will evaporate on hot batteries. It is necessary to turn off the heating and add pressure up to 2.5 bar to determine the place of the leak.

    The next reason may be the leakage of the heat exchanger pipes. To eliminate it, you can solder the heat exchanger, if soldering is not possible, it needs to be replaced. The expansion tank may depressurize or the membrane in the expansion tank has become unusable - seal the tank or change the membrane.

    The tank itself may leak - you can determine this by pressing the spool in the upper part of the tank. If this causes water to spill out, change the tank. How to raise the pressure - you can use a homemade original device consisting of a plastic bottle, a tap and a spool. On plastic bottle, cut a thread on the lid with a tap so that the tap can be fixed on it.

    WITH back side drill a hole to secure the spool to it. We put the spool inside the bottle and fix it. We fill the bottle with water, close the tap and connect the heating system to it through a hose, connect the pump to the spool and, by pumping it, pour water into the heating system. The procedure for pumping water into the system is repeated until the pressure is normalized, up to 1.5 atm.

    109

    Error 109 appears when the overpressure is above 3 bar and is considered one of the infrequent. To eliminate it, you need to relieve the pressure, as prescribed in the instructions for the device, using the Mayevsky crane. if this does not help, it is most likely that the cause lies in the secondary heat exchanger.

    When a partition collapses inside the heat exchanger, it can be a fistula in it, mixing with liquids begins. Water from the mains, which has a higher pressure, begins to flow into the heating system, as a result of which the pressure rises. What to do if this happened - removing the fistula or replacing the heat exchanger will help solve this problem.

    117

    Error 117, according to the instructions for the Ariston BS 24 FF unit, means insufficient circulation. To eliminate it, press the reset button, in this case the system will check and adjust the temperature difference at the inlet and outlet of 3.5 degrees in 8 seconds.

    Reset button on the Ariston boiler - "reset"

    201

    If the circuit breaks or short circuit of the sensor on the supply to the hot water supply circuit, error 201 appears.Check the contacts, they may have oxidized, or the wire has come off, or the sensor itself is faulty and it will have to be changed.

    302

    Error 302 appears on the display when there is no circuit between the control board and the display. The reason may be a violation of the contacts or their oxidation, in which case the contacts should be connected or cleaned. The control board may also fail - replacement is required.

    303

    Error 303 means a malfunction of the main control board, the solution to the problem can only be its replacement.

    304

    Error 304 also appears in the event of a malfunction of the control board and appears if more than 15 resets are performed within 15 minutes.

    Boiler board Ariston

    307,308

    Error 307, error 308 also appears in the event of a malfunction of the control board, pressing the reset button will help to correct the situation.

    501

    Code 501 is described above in the section on most common errors.

    601

    On Ariston Egis Plus 24 (Ariston Egis Plus 24) CF, class 24 FF and others, with an open combustion chamber, error 601 means no thrust. The sensor blocks the operation of the column in the event of interference in the smoke exhaust system.

    This blocking is temporary, after 12 minutes the system will switch to operating mode if the cause is eliminated, otherwise it will repeat again. To eliminate, clean the chimney, if the chimney is free, check the serviceability of the draft sensor.

    604

    Error 604 occurs when the fan speed is low or the Hall sensor is malfunctioning. The fan and sensor should be checked; if a breakdown is found, replacement is required.

    Hall Sensor

    607

    The description of the cause of the occurrence and the remedy is described above, in the most frequently repeated errors.

    a01

    Error a01 blocks the operation of the boiler due to a failure of automatic ignition. It may occur at low unstable voltage in the network, install a stabilizer. The polarity can also affect, in some cases the problem can be eliminated by changing the polarity in the outlet, turn the plug over, changing the phase to zero.

    In addition, there may be problems with the flame ionization sensor.Check if it is clogged, not bent, the wire connecting the sensor to the board may be broken or oxidized. Solder or strip the wire.

    e34

    Error e34 means a failure in the operation of the pneumatic relay when the fan is running. What to do - Check the relay and replace if necessary.

    e108

    Error e108 means a drop in pressure in the heating circuit. The cause and solution of the problem are described above in the description of code 108.

    sp2

    The sp2 (5p2) error means that the second ignition attempt is unsuccessful. If the boiler does not start, there may be several reasons - there may be a problem in the ionization sensor, low gas pressure, insufficient air flow, removal of combustion products. Check the operation of the sensor, the gas valve may be closed or not open enough, open the window and the door, check if the chimney is clogged.

    Ionization electrode

    sp3 (5p3)

    This DTC is described in frequently repeated errors.

    1p1,1p2 (ip2)

    Error 1p1, 1p2 (ip2) appears in case of poor water circulation or lack of it. Causes and solutions to the problem are similar to code 108 and described above.

    6p1

    Error 6p1 appears when there are problems with the air supply and smoke removal, the relay is delayed. to eliminate the problem, check whether there is enough air in the room where the boiler is installed, whether the chimney is clogged, whether the relay contacts are stuck.

    6p2

    Error 6p2 also occurs in case of problems with smoke exhaust and air intake, while the contacts of the combustion product pressure switch open when normal work fan. The solution to the problem is the same as when the 6p1 code appears.

    Boiler pressure switch Ariston

    Other breakdowns

    In addition to those described above, the following codes may appear:

    • 608 - the system generates such an error when the fan starts up, but the pressure switch does not work.
    • Н45 - the last two digits are subject to change. The reason lies in the NTSc sensor, there is no hot water at the outlet, the safety valve is leaking. If there is no hot water, but the heating system is working, most likely the water flow sensor is faulty, clogged with debris.

      Another reason may be that the turbine blades have worked hard, stuck to the body, this can interfere with rotation, replace the blades or the turbine itself.

    The second reason in this situation may be the NTC sensor, to check its performance, measure the resistance at its contacts with a multimeter, if it is unstable, replace the sensor with a new one. If the safety valve leaks, the gaskets may be worn out, replace them.

    NTC sensor

    How to determine the error code if the device has no display or no dial, such as the Ariston BS II 24FF model? Such a device is equipped with indication lights, thanks to which you can determine the breakdown. So, for example, if the indicator 90 and the crossed out water drop icon are on, this means that the boiler has overheated and blocked. To eliminate it, you need to check the pressure switch and its connection to the board.

    Search for breakdowns and malfunctions in boilers Ariston BS

    Gas boiler Ariston BS 24 cannot start. When you hold down the on / off button, the burner works. If you press the key, the unit immediately goes out. Tell me the reason for the breakdown?
    Probably, the thermocouple is out of order or the gas valve is broken. There may still be a low gas pressure in the inlet pipeline. Sometimes there is a lack of voltage on the electronic board.
    A problem has recently occurred. The start is very difficult. The igniter ignites, but there is no fire on the main burner. I just can't understand what is the reason?
    Apparently, damage to the parts of the ignition unit. It is necessary to complete service maintenance the unit and cleaning the ignition device.
    Why did the Ariston BS 15 FF wall-mounted boiler stop turning off when the set temperature is being set? Heating goes up to 85 degrees, then it gives out a breakdown. After the restart operation, the cycle starts again.
    Apparently, the board is not in order, the thermal sensor has a malfunction, the overheating protection button is broken. It is possible that there was a failure in the automation settings.
    I would like to know why the boiler does not heat water above 70C? I need to set more, but the screen says that this is the maximum parameter. How to increase heating?
    If the appliance does not increase the heating circuit temperature, the following factors can be assumed. In the settings, the maximum heating temperature is limited to no higher than 70C. A decrease in chimney draft is observed.
    Ariston BS II 24 FF performs unsatisfactory functions in the mode of heating the DHW system. From the tap flows alternately cold water then hot. Tell me what is causing this malfunction?
    Factors of the occurrence of the problem may be as follows. Cold water is mixed in due to the fact that the three-way valve has failed. The heat exchanger is clogged. You need to clean it up.
    There is a tap under the boiler, and water leaks out of it regularly. The unit itself does not work. What do you need to do?
    Apparently, there is a coolant discharge from safety valve... This symptom indicates an increase in system pressure. In addition, the system make-up valve may be open, or the expander tank should be pumped up.
    Explain why the pressure increases rapidly and at the same time the safety valve opens? The screen always lights up the heating icon in the heating cycle of the device. What to do?
    There is a breakdown of the heating circuit temperature sensor. There is no normal circulation in the heating line.
    What is the breakdown when the BS 24 FF gas boiler constantly turned off? Let's say that today the piezo ignition could not work at all. The boiler maintenance was done at the beginning of the month. What could be?
    We can assume that there are malfunctions in the smoke exhaust device. You must perform a chimney inspection. Incorrect operation of the electric ignition will mean damage to any part in the event of a voltage drop or water ingress.
    Please help me figure out the chimney? For 2 days, reverse draft appeared, while the smoke began to fall directly into the room. I made the chimney myself. It consists of metal pipe... It looks like there was a mistake in the calculations.
    The boiler works fine on hot water supply, and when you turn on the heating, the water quickly comes to a boil, and the device stops working. What is the malfunction, and what is the way to fix it?
    Perhaps the circulation pump is inoperative, the control board is faulty, the temperature sensor is faulty. It is also possible that the filter mesh is clogged.
    At the DHW stage, the unit alternately began to issue either cold or hot water. Help me understand where this comes from. How to regulate water heating?
    The heating system appears to be dirty or the heat exchanger needs to be cleaned. In addition, the pressure monitor may be defective or the circulation pump is defective.
    The main reason may be the incorrect configuration of the chimney duct. Sometimes there is soot contamination that lowers its coefficient sufficiently useful action... In addition, it is recommended to check the ventilation in the room.
    The gas boiler Ariston BS is in operation. The device instantly sets the temperature up to 96 C, and then rises due to overheating. Later, when it cools down, it goes to reboot. How to fix the breakage?
    Failure of overheating functions means that there is no circulation in the system. It is mainly necessary to control the position of the radiator valves. They need to be opened. After that, a check is carried out for contamination of the filter element, and it is also necessary to make sure that the heat exchanger does not contain dirt.
    Carried out the connection of this unit in 2015. Approximately after 2 months, the device suddenly began to make noise. Explain why the noise is happening?
    Most likely, there is scale in the heat exchanger. If the water is hard, then over time, lime will be deposited on the walls of the radiator pipes.
    I am going to connect the Ariston BS II 15 FF boiler to heat the house. Please tell me what is the right way to put it into operation yourself?
    For the correct start-up of the boiler apparatus, the following steps must be taken. We connect the power supply to the device. We open the gas tap. Then we start the burner device. Then adjust the desired temperature.
    We want to carry out maintenance. Advise how to drain the coolant from the apparatus?
    According to the guide, this work is produced like this. Disconnect the device from the network. Close the gas valve. We open the automatic air vent. Open the drain cock. Then collect the spilled water. Alternatively, you can drain the water using the relief valve. This valve is located at the bottom of the apparatus.
    Explain to me how to diagnose a 3-way valve? I think it does not open correctly. In heating mode, it pumps out distant batteries weakly, however, a pipe for supplying heating water under the boiler unit heats up on the DHW.
    That's right, it is necessary to inspect the three-way valve for the presence of acidification of the stem in an intermediate state. We also recommend diagnosing the heating system itself.
    I have a BS 24 CF boiler in my house. Until that time, he performed functions properly. V this moment after 1 minute after the start, the device goes out.
    It seems that he is unable to force water into the system. Explain what is this reason? A likely factor for this damage may be the ignition electrode, which does not see the flame, or the lack of circulation.
    Just yesterday, there was a problem with this unit. While working, he began to whistle. I tried restarting - it succeeded, but no changes happened. Perhaps someone will tell you what the problem is?
    Very often, a sharp whistle occurs when the pressure setting on the nozzles of the gas burner device is incorrectly adjusted. Need to check adjustments gas pressure and fix it if necessary.
    The boiler has recently been filled with water, and the unit began to function with errors. For example, if you set any temperature, and the heating mode reaches only 22 degrees, and then the unit stops. Could you tell me what happened?
    If water gets on the control board unit, it can be assumed that it does not work correctly. We advise you to reset it to zero by completely disconnecting the unit from the mains. Then turn it on again and test its performance.
    The device of the same model was put into operation two years ago. Today, at the moment of start, the wick burns for 8 seconds, but the main burner does not support the flame, and because of this, the apparatus goes out. How can you fix the breakage?
    Probably, the automatic ignition is faulty or problems with the burner. In any case, it is necessary to check whether the phasing is not violated at the time of connection to the electrical network.
    I carried out the commissioning of the same model myself in the middle of this year. After about 4 months, a malfunction occurred in the DHW circuit, but the heating mode is operating normally. I tried to open a hot water tap, but the device only displays the temperature, and does not even think about heating. Why is DHW not working?
    Most likely, the 3-way valve is faulty. It needs to be replaced.
    Tell me why the boiler is equipped with a safety thermal sensor?
    This part shuts off the gas supply to the burner when the water overheats in the main heat exchanger.
    The primary heat exchanger needs to be flushed and cleaned. Can you tell me what needs to be done in order to professionally disconnect it?
    The main heat exchanger can be easily removed from the boiler unit using a conventional screwdriver. The following is the order of dismounting. We drain the water from the device using a drain cock. Then we empty the DHW system. Loosen the screws securing the heat exchanger and pull it out of the frame.
    Started this unit. Presumably after three months, the water pressure in the apparatus dropped. Often it will slow it down and stop working. In other words, it absolutely does not hold the pressure. Why is this happening?
    If the device does not increase water pressure the make-up tap is probably leaking. When a shutdown occurs and the water pressure drops sharply to zero, then the 3-way valve is damaged.
    Tell me how to clean the cold water filter?
    The initial stage is to drain the water from the DHW circuit. Secondly, unscrew the flow sensor nut. Then we take out the sensor and filter from the cavity. After that we clean from accumulated impurities and dirt.
    The device could hum at startup before, but at this time it makes much louder noise. Initially, the sound quickly disappeared, but now it lasts longer. Has anyone observed this issue?
    The appearance of excess noise indicates the presence of mineral deposits inside the heat exchanger, the heating of which is uneven due to different thickness walls. The more dirty the heat exchanger, the more pronounced the rumble, and, accordingly, the heat transfer decreases.
    The unit is functioning, although water does not seem to be circulating in the system. The pump acting on the return flow heats up noticeably. How do I fix this?
    Apparently, the mud filter is clogged or the tap is closed somewhere, which interferes with the passage of the coolant. The circulation pump may also be faulty.
    What causes the hot water to stop heating? The water comes out very warm. Explain what happened?
    Clarification of problems is carried out in the following directions. If the DHW temperature sensor is damaged, it should be replaced. Perhaps there was a failure in the settings of the device's power for heating DHW.
    Flame breakage is periodically visible during ignition. The burner is clean, everything is normal with the chimney, the draft is good. What could be the malfunction?
    The unit does not detect a spark due to weak signal from the combustion mechanism. Here you need to check the wire between the ionization sensor and the electrode. You probably need to tighten it up. There may also be damage to the sensor insulation, which must be replaced.

    • Gas boilers
    • Electric boilers
    • Boiler error codes
    • Elimination of malfunctions in boilers
    • Gas water heaters
    • Malfunctions and repair of gas water heaters
    • Water heaters
    • Troubleshooting water heaters
    • Repair of indirect heating boilers
    • Elimination of malfunctions in electric convectors
    • BAXI ECO FOUR

    Heating system control. Mounting. Connection. Transfer to another type of gas. Adjustment devices and protection devices.

    • BAXI LUNA

    Peculiarities. Installation and assembly. Automation components.

    • BAXI MAIN FOUR

    Technical specifications. Mounting. Adjustment and check. Maintenance.

    • BAXI SLIM

    Regulation and protection. Installation and assembly. Pressure setting. Maintenance.

    • BAXI - REPAIR

    After starting, a malfunction appeared. He does not want to turn on, he worked for two years, now the entire panel is on fire as if the boiler is turned on, when the self-diagnosis mode is on, then it clicks, turns off for miles and then turns on the entire panel again. It turned on once, but gives an error E10 water pressure, although the pressure in the system is 1.5 atm. Tell me what could be?

    • BAXI - OPERATION
    • BAXI - SETTINGS

    We installed and connected a Baxi Fourtech 24 F boiler. What cold water pressure is allowed at the inlet to the DHW unit?

    • BOSCH - REPAIR

    Bosch 6000 boiler 24 kW, single-circuit with a built-in three-way valve. Does not see the boiler sensor, gives an error. Tell me how to make sure that it does not give an error and work normally both for heating and for a boiler?

    • BOSCH - ADJUSTMENTS

    If you turn off the DHW flow sensor, can it be possible to reprogram it into a single-circuit device through the L3 menu?

    • ARDERIA - REPAIR

    Installed the Arderia esr 2.13 ffcd boiler. If my coolant pressure drops a little in 2-3 days for a couple of divisions, can there be a reason for the malfunction of the three-way valve (there are no leaks from the radiators)?

    • ARDERIA - ADJUSTMENTS

    The gas boiler Arderiya 2.35 is in operation. Tell me about the power reduction. I heard something about modulation, fan speed and so on. Is it possible to really reduce the power?

    • BUDERUS FLOOR

    We installed and connected a Buderus Logano G234-WS-44 kW boiler, Logomatic 4211 automatic equipment. Heating on cylinders without hot water supply, nozzles for reduced gas were also replaced. We survived the winter, the cylinders were replaced, all without problems. Then in the spring, when the temperature outside is + 16 + 18, the boiler began to turn off for a long time and, when turned on, began to display a burner error on the screen and a red button lamp on the front wall lit up. We pressed the button, turned on the power again and everything worked. It happened several times, then for the summer they turned off the boiler completely, what could be the malfunction?

    • BUDERUS WALL

    In a single-circuit Buderus 072, is the BKN coil circuit heated by the same heat exchanger as for heating or the same as on the 2-circuit one that is on the DHW?

    • VAILLANT - REPAIR

    Tell me, for Vaillant wall-mounted gas boilers, are there any real / actual differences in better side in the new generation turboTEC plus VU / 5-5 versus / 3-5?

    • VAILLANT - ADJUSTMENTS

    There is a malfunction in the operation of the boiler, the green LED (power) is flashing, the instructions say that the thermal protection has worked, the green indicator is flashing, even if nothing is connected to the board. How to fix? I checked all SMD resistors and transistors, everything is in order.

    • DAEWOO

    A double-circuit gas boiler Daewoo Gasboiler with an electronic panel is in operation. When the DHW is turned on, the heating heats up, the operating mode is summer. I took off the three-way valve, there is no dirt and production. It seems that the board does not control the three-way valve. How to check?

    • ELECTROLUX

    The wall-mounted boiler Electrolux Basic Xi ​​is installed and connected. A malfunction began that the boiler stopped seeing the flame and turned off the gas supply after 7-8 seconds. And after 3 attempts, it gave an E1 error. How can you fix it?

    • KOREA STAR

    Malfunction of the Koreastar boiler. Heating works perfectly, hot water is intermittent, when the hot water tap is turned on, cold water comes first, then boiling water. After a few seconds, cool, then boiling water again. What could be the problem?

    • FERROLI

    Malfunction of the ferroli domiproject 24 boiler - I adjust 60-70 degrees, it goes to minimum combustion, does not turn on, does not turn off. Restarting is unstable. No pattern is revealed. What to do?

    • JUNKERS

    In operation, the gas boiler Junkers euroline, when hot water is turned on, ignites the gas, then goes out and so on several times. If you turn it on while the heating is running, then the water heating turns on immediately. Can you please tell me what could be the problem?

    • NAVIEN

    Tell me about the adjustments of the gas boiler Navien Ace 16 turbo remote control v1.3. Fan overrun cannot be set. I bet 30 seconds, but still 2 minutes. twists.

    • OASIS

    Malfunction of the boiler Oasis ZRT18. The unit starts up, the gas is ignited, then it goes out. Again it lights up and goes out (three times it happens). Then it flares up and works fine. It does not give any error. What is the reason?

    • SAUNIER DUVAL

    Malfunction of the gas boiler Senor Duval - the water pressure sensor shows 0.0, the indicator flashes red, hot water does not heat up, but the water pressure in the apartment is good. How do I fix the problem?

    • VIESSMANN

    In which place coaxial chimney Should a condensate drain be installed? Boiler wh1d with a closed combustion chamber, located at a distance of 1m from the wall.

    • WESTEN

    The problem of starting the Westen Pulsar D boiler. Piezo ignition works, but there is no flame, after a crackling error E01. Rearranged the fork in places.

    • BERETTA

    The Novella floor-standing gas boiler has blocked - the green lights on the panel are on, and nothing else happens. How to fix?

    • ARISTON

    An Ariston gas wall-mounted boiler was installed and connected, which does not hold pressure at all: during the cooling of heated water, the pressure drops to zero, although water is regularly drawn. What's with the pressure?

    Malfunction of the metropolis dgt 25 bf boiler. The hot water supply stopped working, the heating is working, it does not give an error. What do you advise?

    • SOLLY

    Please tell me how to solve the problem. The Solly Standard boiler, with any attempt to turn it on or hot water, gives a GS error.

    The Wolf boiler is in operation. Recently, he began to behave strangely: in the pause between starts, he turns on the burner for one second five times, and 70 degrees jumps out on the display. Where to look for a malfunction?

    ACV Wester Line works very unstable: it often goes into an accident, when it starts up, it emits a characteristic knock and stalls, and at times everything is fine. The unit is almost new, what's wrong with it?

    • DEMRAD

    In the gas boiler Demrad, gas is no longer supplied to the burner. The piezo element clicks, but there is no ignition. WITH gas stove everything is in order, there is gas. What is the reason?

    • KITURAMI

    Malfunction of the Kiturami world boiler, it stops periodically. I wipe the flame sensor and the apparatus works well for a while, but soon everything repeats itself. He also began to smoke heavily. Maybe it's a short chimney, and you need to lengthen it?

    • IMMERGAS - ERRORS

    Errors of boilers Nike Star, Eolo Star / Mini, Mythos. Boiler malfunctions with the possibility of automatic unlocking.

    • IMMERGAZ - REPAIR

    I have a boiler in winter mode systematically raises the temperature up to 80 degrees. I summoned the master three times. He said that this is for many imergaz models, and offered to install a programmer, but not the fact that it would help. Tell me how to solve this problem and will this programmer help?

    Model 11.6; 17.4; 23.2; 29.3 kW. Specifications... Control elements of the automation unit. Installation and maintenance. Malfunctions and their elimination.

    • AOGV - REPAIR

    The gas boiler AOGV was installed and put into operation. Hot water dispensing problem. The heat exchanger has been flushed. Less than a month has passed, and again the water does not flow. We put a filter on the water, but time passed, and again hot water does not flow. What could be the breakdown?

    Assembly and installation. Start-up and adjustment. Malfunctions and ways to eliminate them.

    Technical specifications. Installation and connections. Startup and work order. Automation adjustments.

    • NEVA LUX

    Malfunction of the boiler Neva lux 7023. With a frequency of 2 times a month, it gives an error E7. But after a reboot it still works. Now it gives an error E6. It will work for 15 minutes, and then it turns off. What could it be?

    Construction and automation unit. Firing up procedure. Malfunctions and repairs.

    • ATEM ZHITOMIR

    Tell me, is it possible because of the weak gas pressure that the Atem Zhitomir boiler goes out, it clicks and goes out. What is the problem? Is it possible to turn off the automation for a while and how?

    • LEMAX

    A gas boiler Lemax KSG-12.5 Premium was installed. After turning off the main burner, a click occurs after a couple of minutes, what is the reason, tell me?

    • KEBER

    A gas boiler KS-G was installed and connected, for 250 sq. m. When firing up, it does not turn off, the temperature rises, if I am not mistaken, the automatic Arbat 1. The flame is not regulated - too large. What to do?

    I installed the Mayak gas boiler and connected it. It works fine. But the reason is this. When it works on a unit, it beeps strongly, if the knob is turned 2-7, the squeak disappears. Tell me what could be?

    • DANKO

    We installed and connected the Danko gas boiler with the Kare automatics, it works fine on the igniter, but it is worth adding the power on the burner, it completely dies out, yesterday it faded out for 5 minutes, today it works for 20 minutes and completely goes out. Who faced this problem?

    • GAZLUX

    The boiler gazeko 18 is in operation. When hot water is turned on, the pressure in the system drops after make-up, the pressure reaches 3 bar. Have to dump. What's the matter, how to fix it?

    • NOVA FLORIDA

    Water often boils in the boiler, while it goes into an overheating accident. The heat exchanger was recently washed, the system is not clogged. What's the matter?

    • RINNAI

    Malfunction of the Rinnai 167 RMF boiler. Recently I started showing error 14. How can you fix the breakdown?

    • CELTIC

    The Celtic ds boiler heats up to 45 degrees and costs the whole day it does not turn off and does not heat up the batteries, sometimes it shows an a3 error. How can this problem be resolved?

    Double-circuit gas appliances make our life more comfortable and enjoyable. They are quite practical to use, suitable for heating country houses and small apartments. They are used for heating industrial or warehouse buildings, the area of ​​which is not more than 500 sq.m.

    The advantages of Ariston boilers are that in addition to heating buildings in winter, they heat water used in everyday life all year round. It is quite convenient and does not require the installation of additional equipment.

    General characteristics of Ariston boilers

    The description of Ariston gas units must begin with the characteristics of their main part - the burner. This element is used to burn fuel and to transfer thermal energy to the heating system.

    Types of boiler burners:

    • common
    • modulation

    The modulating burner is more convenient to use. It provides for automatic power regulation depending on the temperature of the device.

    By the type of removal of combustion products, burners are divided into:

    • closed type
    • open type

    Units with a closed burner are safer to use. In this case, the combustion products of natural gas do not enter the room. No use required. A coaxial pipe is simply connected to the device and brought out.

    The design of the coaxial pipe provides for the presence of two layers, which ensures the simultaneous removal of waste and the flow of air from the street into the burner.

    Equipment with an open burner provides for the mandatory use of a chimney to remove combustion products.

    Ariston Gas Appliances Technical Data

    • Ariston boilers are used for heating and water heating, that is, they are double-circuit. Each modification has its own characteristics, but the common thing is the type of fuel - gas.
    • The gas combustion chamber can be either open or closed. In the presence of a chimney, units with an open chamber are used. And in apartments of multi-storey buildings, where chimneys are not always available, equipment with a closed combustion chamber is used.
    • Power. This indicator is used to calculate the gas consumption required to heat the room.
    • Compactness. Wall mounted appliances are used in small, narrow rooms. Floor-standing units used in production or storage areas are heavier and require more installation space.
    • The presence of a control unit. This element is indispensable when the water is turned off, the gas drops sharply. In case of any malfunction, the unit will immediately turn off the device, which will prevent damage. It also helps to save fuel consumption.
    Ariston boilers are used for heating and heating water, that is, they are double-circuit

    Characteristics of Ariston boiler models

    A distinctive feature of Ariston boilers is their high quality. After all, the name of the company is translated from Greek as "the best".

    Her products are especially popular with middle-income consumers. Gas boilers of this brand are purchased for heating rooms up to 500 sq. The company's products are universal. The transition to liquefied fuel is carried out only by replacing the burner.

    Two-circuit wall-mounted gas appliances are practical to use. It is represented by three lines, each with its own modifications.

    For all modifications of boilers, the following is common:

    • small size.
    • hot water supply, in the absence of its centralized supply.

    Different modifications differ in structure, the common thing is their low cost and high-quality performance of parts.

    Basic configuration of units from Ariston:

    • double.
    • electronic control module.
    • control of carbon monoxide.
    • microclimate support in a building or in a separate apartment.
    • control of water freezing inside the system.

    Let's take a closer look at the existing types of Ariston equipment.


    Ariston genus

    • Available with double heat exchanger. All modifications are double-circuit and are mounted on the wall.
    • This model is considered the most functional of all Ariston devices. Has an LCD display, a control panel with buttons. Ariston Genus can be configured to operate autonomously for an entire week.
    • The display shows basic data about the device status and a list of possible errors. The burner is modulating, that is, it is fully electronically controlled. This function increases the comfort of using this model of gas appliance, due to the minimum control by the consumer.

    The Ariston Genus line includes the Evo and the more expensive Premium models.

    The Evo model is a double-circuit gas appliance with both types of burner: open and closed.

    Genus Premium condensing boilers. They are used for heating residential buildings and commercial buildings. Power range from 24 kW to 35 kW.

    Ariston clas

    • The device is small.
    • This is a boiler with two circuits and a graceful appearance. The reduced size did not compromise its functionality in any way.
    • Expansion tank 8 l. Hot water heating is fast enough

    Existing modifications:

    • Evo is available with open and closed combustion chambers. Power with an open burner - 24 kW, with a closed one - 24 - 28 kW.
    • Premium Evo is a condensing unit. Has extended comfort and freezing functions
    • Premium simple condensing unit.

    Ariston egis

    • Installed predominantly in rooms up to 200 sq.
    • The most common model of the Ariston gas appliance in our country. Heats water with a stainless steel heat exchanger, and a copper heat exchanger is used for heating.
    • A compact device, it is economical and can be used in difficult weather conditions. For example, at sharp subzero temperatures.
    • The appliance is equipped with a modulating gas burner, which allows electronic control over the operation of the boiler.

    This model is adapted to work in harsh climatic conditions. Normally withstands gas pressure differences. The device is equipped with a collector into which the condensate flows. This ensures operation at temperatures below 50 degrees.

    Cost of Ariston boilers

    The average cost of Ariston Genus boilers is 54,000 - 72,000 rubles, Ariston Clas - 25,000 - 34,000 rubles, Ariston Egis - 27,000 - 34,000 rubles

    Choosing a gas appliance for heating

    Ariston products can be found in catalogs. There are many models of gas appliances. The main mistakes when choosing the wrong unit are made from a lack of information. Therefore, before visiting the store, you should familiarize yourself with the basic tips for choosing a wall-mounted gas appliance.

    When choosing a boiler, take into account the following points:

    • The size of the kitchen, as the place where the heating appliance is most often installed. In the store, the choice begins with considering the overall dimensions of the device and selects it individually for your kitchen.
    • Next, they go to the technical data and study the type of water heater in the apparatus. If there are a large number of people in the family, then it is not recommended to purchase a boiler with.
    • In this case, it is more rational to purchase a boiler with a storage tank for hot water. and select equipment for the amount of water that you will need for everyday use.
    • The combustion chamber of the gas equipment is evaluated. It can be closed and open. It is recommended to choose a boiler with a closed chamber, due to the fact that it is safer to use. The presence of a chimney is optional, which is important in multi-storey buildings. Enough to buy and bring out a coaxial pipe.

    As a rule, we trust the masters from the service centers to start the gas boiler for the first time and work on setting it up and adjusting it. Why? Yes, because without their marking in the equipment passport, the manufacturer's warranty is simply not valid, and in the event of an early breakdown, we will simply be denied warranty repair.

    Whether this is actually the case is a controversial question, of course. Specialists from the service center will find a million reasons to deny you free repair equipment. And even if you get such generosity from them, then your repair will last more than one week - then there are no spare parts, then the queue has not come yet, then it is wrong. This is a proven fact and it is very difficult to refute it. Want a quick " warranty repair"- pay both for spare parts and for the work of the master.

    By the way, in order to put the boiler on warranty service, you also need to pay money. So what is the guarantee? Pay for the warranty, then pay for parts and repairs. So where is the free warranty service? That is why, since you have to pay for everything anyway, I propose to independently make the first start of the gas boiler and set up the heating system. Moreover, it is not difficult.

    We fill the heating system with water

    We look under the bottom of the boiler - to where all the pipelines are connected, and we are looking for something like a small valve there. For each model of gas boiler, it can have different shape: one manufacturer makes it in the form of a valve familiar to us, the other in the form of a rotating plastic pin. In general, from their form, the essence does not change - as a last resort, open the instructions and see its location.

    We open this tap, not completely (so that air does not hang anywhere in the pipes, it is better to fill the system slowly) and direct our gaze to the pressure indicator - a manometer. As a rule, most boilers of this type have operating pressure from 1 to 3 Atm - read more precisely in the instructions. We are waiting for the pressure gauge needle to reach 2.5 Atm, close the valve.

    Now the boiler will have to be left alone for a while - from each installed battery or the convector must be vented.

    For these purposes, each heater must be equipped with a Mayevsky crane. We open it and wait for the air to come down and some water to run. The water went - they turned off Mayevsky's tap. This procedure must be done with each battery. Have you done it?

    Now we return to the boiler and again look at the pressure gauge - the pressure in the system should drop. We correct it, add water if necessary - the optimal pressure at which the boiler operates normally is 1.5-2 Atm. If you pump more, then during operation at a high temperature of the coolant, excess pressure will be released. This is due to the fact that when the liquid is heated, its pressure increases.

    First start-up of a gas boiler

    Having done all these ingenuous preparations, you can proceed to the direct start of the boiler. We open the gas valve and plug the boiler into an outlet. All sorts of symbols and numbers appear on the screen, but for a full-fledged start, you still need to perform some actions.

    First, press the power button and set the temperature control knobs to the working position. After these actions, the boiler will begin to make vain attempts to turn on - this is normal and there is no need to be afraid. The most important thing is that a circulation pump was switched on, inside of which, for some reason, there is always air that interferes with the full activation of the boiler. It is its removal that needs to be dealt with as quickly as possible.


    Remove the front cover of the boiler - in almost all cases it is fastened with two or four screws. We fold back the dashboard, behind which the circulation pump is hidden.

    There is a wide screw with a slot for a screwdriver in the center of the pump. Here is his darling and you need to unscrew a little, and when water runs out from under him without air bubbles, spin again. Only now the full circulation of the liquid in the heating system will begin, and the boiler will start working.

    At first, he will gurgle, make some strange sounds, but this is only for the best. Just be aware that all these sounds indicate that the remaining air in the system is expelled into the expansion tank, where an automatic air valve releases it outside. Five minutes will pass and the system will return to normal - the pressure will stabilize, and the gurgling sounds will subside. And after another five minutes, you will already be enjoying warmed up batteries and unlimited hot water in the tap.

    That, in principle, is everything you need to know in order to carry out the first start-up of a gas boiler. The boiler is working, the batteries are warming up, and I think you can figure it out for yourself how to regulate the temperature of the batteries and hot water in the tap - read the instructions, everything is clearly described there regarding the control of your particular boiler model.

    Was this article helpful? Subscribe to site updates to receive the latest articles on renovation and interior design before anyone else!