Errors of gas columns Neva Lux. Errors of neva lux boilers and their codes The device works fine in DHW mode, but does not work for heating the house

In chapter Service, maintenance and repair to the question Boiler neva lux 8224. constant error 03. condensate accumulates in the pressure switch tubes. How to fix this problem. given by the author Vladimir the best answer is Need more detailed information about where it is located, the outside temperature, fuel (gas or diesel fuel), winter or summer, etc. And condensate from what (water, gas)?
What can be done to prevent condensate from collecting in the pitot tubes? The Neva Lux 8224 boiler turns off every year in January, showing error 03. Of course, I eliminate the condensate and start the boiler until the next accumulation of condensate, but this problem is pretty boring. Help!

Answer from Yotas Shabanov[guru]
1. Check if the tap is completely closed.
make-up.
2. If the make-up valve is closed all the way, then
it is possible that the make-up valve is not tight.
Replace the make-up valve.
3. Check if the secondary heat exchanger is leaking.
4. Also check if the sensor is working properly
pressure and connectors of its contacts.
Another option: opening the plug on the right side
above, in order to enter the combustion chamber
warm air and not
condensation formed in the presostat tubes.



Wall mounted gas boilers Buderus
Logamax models U042, U044, GB072, GB172. With open and closed chamber combustion. Repair and service methods, adjustment of operating parameters. Recommendations for maintenance.
Gas heating boilers Vaillant
Models: floor-standing Atmovit exclusiv, wall-mounted condensing Ecotec plus. Service, maintenance, settings of functional components. Hydraulic diagrams.
Gas wall boilers Ariston
Clas, Clas Evo, Genus models. Recommendations for repair, maintenance and service. Elimination of errors and malfunctions. Setting and adjustment methods.
Gas boilers Immergaz
Models Eolo Star, Eolo Mini, Nike Star, Nike Mini, Metos. Repairs and adjustments. Installation, assembly and connection. Operating mode settings and additional equipment.
Kentatsu Furst boilers
Wall models Nobby Smart. Condensing Smart Condens. Floor standing Sigma, Kobold. Solid fuel Elegant, Vulkan. Malfunctions and error codes. Description and characteristics.


Errors of the Neva Lux boiler and their meanings

Error 01 (E2)- Malfunction associated with unsuccessful ignition or overheating of the heating medium. The boiler is not functioning.

Code 01 for models Neva Lux 7023, 7224, 8224. Code E2 - Neva Lux 8023, 8029.

Burner clogged. Clean burner and nozzles. The ignition electrode is faulty, its electrical circuit is broken, the gap between the ignition electrode and the burner section is incorrect. Check the electrical circuit and contacts, set the correct gap (4-5 mm). Replace the ignition electrode. The ignition transformer is defective or its electrical circuit is broken. Check the electrical circuit and connector contacts in the control unit. Check and, if necessary, replace the ignition transformer. The ionization electrode is faulty, its electrical circuit is broken, the gap between the ionization electrode and the burner section is incorrect. Check the electrical circuit and contacts, set the correct gap (3-3.5 mm). Replace the ionisation electrode. Also, in case of error 01 (E2), the coolant overheating sensor in heating mode may be triggered. Find and eliminate the cause of the coolant overheating. The coolant overheating sensor is faulty or its electrical circuit is broken. Check the electrical circuit and contacts. Inspect the overheating sensor (must be closed at temperatures up to
95C). No flame due to gas valve failure. Check for contact in the valve connector and in the control unit. Replace the valve if necessary.

Error 02 (E7)- Overheating of the coolant

Code 02 for models 7023, 7224, 8224. Code E7 - models 8023, 8029.

The fan is damaged (the motor winding is burnt out, the bearing is jammed, the impeller is jammed, the fan's electrical supply circuit is broken). Check the continuity of the circuit and contacts in the connections. Ensure free rotation of the impeller. Replace fan if necessary. Also, in case of error 02 (E7), the coolant overheating sensor may be faulty or its electrical circuit may be broken. Check the electrical circuit and contacts. Check the overheating sensor (should be closed at temperatures up to 95C). The coolant overheating sensor has triggered in heating mode. Find out and eliminate the cause of the coolant overheating.

Error 03 (E6)- Malfunction in the combustion products removal system

Code 03 for models 7023, 7224, 8224. Code E6 - models 8023, 8029.

Chimney or duct blockage supply air... Clean the pipes. The supply pipes or the housing of the air pressure switch are damaged. Repair damage or replace tubing. The electrical circuit of the air pressure switch has broken. Air pressure switch defective. Check the continuity of the circuit and contacts in the connections. Replace the sensor.

Error 04 (E1)- Lack of water pressure or lack of circulation in the heating circuit. The device does not start.

Code 04 for models 7023, 7224, 8224. Code E1 - models 8023, 8029.

Small amount of water in the heating system. Top up the heating agent in the heating circuit to the required pressure. There is air in the heating system. Remove air from the heating system. Clogged dirt filter in the heating circuit. Clean the filter. Bypass valve defective or incorrectly installed. Check and, if necessary, replace the valve. Failure of the circulation pump. Replace the pump. Even with error 04 (E1), there is insufficient mobility or souring of the stem of the flow sensor in the heating circuit, which transfers movement to the microswitch, rupture of the membrane of the flow sensor. Remove the microswitch from the flow sensor housing. By switching the boiler on and off again (turning on and off the pump), release the stationary stem; if this does not help to check the integrity of the membranes on the flow sensor. Microswitch defective or electrical circuit broken between microswitch and control unit.
Check the electrical circuit and contacts in the connector of the control unit. Replace microswitch. Failure of the servo motor of the three-way valve drive. Replace the servomotor. Gas supply interrupted. Check the presence and pressure of gas at the inlet to gas unit... Click on the Reset button. Incorrect phase connection when connecting the unit to the mains. Make the correct connection of the phases.

Error 05 (E3)- Failure of the heating circuit temperature sensor. The appliance does not work in either heating or DHW mode.

Code 05 for models 7023, 7224, 8224. Code E3 - models 8023, 8029.

The temperature sensor of the heating circuit is defective. Replace temperature sensor. Violation of the electrical circuit temperature sensor - control unit. Check the electrical circuit and contacts.

Error 06 (E4)- Damaged DHW temperature sensor. The boiler will continue to operate in heating mode and in hot water supply mode.

Code 06 for models 7023, 7224, 8224. Code E4 - models 8023, 8029.

DHW temperature sensor malfunction. Replace the DHW temperature sensor. Damage in the electrical circuit DHW temperature sensor - control unit. Check the electrical circuit and contacts.

Error E8- Communication error

The loop connecting the controller board with the control board is damaged, or there is no contact in the loop connectors. Check the integrity of the loop and the presence of contact in the connectors. Replace the ribbon cable if necessary. Control board malfunction. Replace the board. Faulty controller board. Replace the board.

Error E9- Supply voltage out of permissible limits

The boiler supply voltage is outside the range of 180 - 250 V. When the normal supply voltage is restored, the device will turn on automatically.

Troubleshooting

For 2 years I have been operating a Neva Lux gas boiler manufactured by Baltgaz. Now defects began to appear in his work. If you use it for a long time hot water, the pressure in the system drops and it stops by error 04. Although the pressure gauge shows the same pressure of 1.6 bar. Has to
constantly use make-up. How can I fix this?

Perhaps in your expansion tank the pressure is lower than it should be. It is then that error 04 is possible.

Six months ago, I installed a double-circuit boiler Neva Lux 8230. Recently I encountered such a problem. When hot water was required, I turned on the tap as usual. At first it went warm, and then cold again. Error 02 appeared on it at that moment. I tried to reset it with the "reset" key, but after that the heating turned on. After that, hot water was required again in the evening. I turned on the tap and everything worked fine. The device worked for 4 days without problems, but today the error appeared again. I studied it more carefully. It happens like this. After the transition to heating water for DHW occurs, a sound is heard inside, similar to air intake. At the same time, you can observe the instability of the manometer readings (approximately 0.5 in each direction). And all this is accompanied by the same strong sound not only from itself, but also from the membrane tank (additional, external for 18 liters). After that, the pressure rises sharply to 5 bar. It turns off, the water temperature drops to 23C. And error 02 is displayed. The instructions say that I have air in the heating system, but I work with hot water supply. What's the connection? Maybe my 3-way valve is broken? Or is the filter in the heating system clogged?

Error 02 - the coolant is overheating. The fan may be broken or the sensor is damaged.

My boiler Neva Lux 7023 stops about 2 times a month by error 07. Restarting always solves this problem. And now a new error has appeared - E5. It works for a quarter of an hour and turns off. What happened to him?

Error E7 means that the coolant is too overheated. Perhaps you have a heat exchanger with inside all in scale, and because of it there is poor circulation in the system. Did he start making some unusual noise with you? But regarding the E5, here you need to pay attention to the pressure switch or the fan. It is necessary to look at both that and that. In an amicable way, this problem should be solved by a specialist. Also, just in case, check if your chimney is icy.

The unit showed error 03. As I understand it, it means problems with the fan. When checking, I applied voltage to it - everything is normal. I also checked the pressure switch - it is also working properly. It turns out a relay on the board? A couple of years ago I came across a similar one. But then an acquaintance helped me out, giving from his old unit. Tell me, is it possible to work somehow without this relay? I tried to manually spin the fan, it started to work, but the gas did not come in. Is the same relay responsible for this? But now the error was 01.

In order for the relay to work longer, you need to set it up more carefully. gas valve and heating power, and it is advisable to install a room thermostat. All this not only increases the service life of the device, but also saves gas. To solve error 01, you need to check the voltage on the gas valve, whether it opens normally and whether gas is flowing. It is better to call a specialist, since all these checks are life-threatening. And the master has a diff. pressure gauge for assessing gas pressure. And so, most likely you have little house and you did not tune the system for the heated area. So a room thermostat is the best solution for you.

Help me please. In our new apartment, even before us, a wall-mounted dual-circuit NevaLux 7218 was installed. During the day, it constantly stops by mistake 04. They began to feed, then the temperature began to drop. And now water has also flowed out of it (in the place where the heating pipe enters it). I had to turn it off. So you can't use it?

It is necessary to check the pressure switch. In the chimney, a small air exhaust pipe could be blocked.

My wall-mounted boiler Neva Lux 7023 (Baltgaz) has a problem with hot water supply. With heating, everything is normal, and as soon as I start parsing water, error E2 appears. This does not heat up the water. If the water is turned off, then it is perfectly normal to continue heating the apartment. The water pressure is consistently good. I looked in the instructions, it says that E2 is an error of unsuccessful ignition or overheating of the coolant. During DHW operation, the burner starts working and burns for 2 seconds. Then the thermometer shows a temperature of 95C, immediately turning off the device and an error. The water runs warm while the burner is on. What could have broken?

Try to check the DHW temperature sensor, perhaps this is the case. Although, in theory, the E2 error symbolizes problems with ignition, but then there would be no heating.

My boiler produced by Baltgaz, installed on the wall, at first did not want to switch from the mode heating system for hot water supply. Although, sometimes, for reasons I do not understand, it still worked as it should. First of all, I checked that all contacts were in good working order, then I checked the electric motor of the three-way valve. If you clamp it with a screwdriver, then the valve is in good order and works as it should. If you switch the mode (with the engine removed), then everything works. The movement of the stem is noticeable and consistent. Contacted service center... The master who came to me suggested that the problem was in the flow sensor. He did not see the signal coming to him. We need a new one. But he did something to make the device work. It did not work for a day, and then I needed to turn it on. And it won't start. The indicator blinks, all possible symbols are highlighted. The reboot did not help. Disconnecting the power supply did not help either. What could be the problem?

Take out the connector on the board, and disconnect the wires one by one. First of all, those that are responsible for the drive of the three-way valve. Then reattach them. This should fix your problem.

I just can't fix the Baltgaz Neva boiler. Error 03 constantly appears, the fan does not work during ignition. If you blow on the pressure switch tube, then it starts spinning. The device does not want to turn off on its own, you have to do it manually. How to be?

Find the hatch in the upper right corner. You need to open it and restart it.

Other malfunctions

Lack of spark for ignition.

Ignition plug defective or poorly installed. Correctly install the spark plug (the gap between the end of the spark plug and the burner section is 4-5 mm) or replace it. Loose contact between terminal and ignition wire. Check the contact of the terminal with the ignition wire. The ignition electrode is dirty. Wipe the electrode from dust and degrease.

The boiler does not turn on.

Lack of gas. Lack of water. Lack of electricity. Carry out appropriate checks (incoming gas, presence of water, connectors, fuses). Burner nozzles clogged. Clean the nozzles.
Air in the gas circuit. (May occur after prolonged inactivity). Turn on the unit several times until the error is eliminated. Fuse blown. Replace the fuse on the controller board. The temperature sensor of the heating circuit has been triggered. Check pump operation. If the pump is running, check the sensor. Defective gas valve. Repair or replace the valve. Deactivated boiler. Switch on the device again.

Pops in the burner.

Gas supply problems. Check the gas pressure upstream of the unit. Dirty burner. Check and clean the burner. Insufficient air supply. Clean the burner. Poor flame control. Check gas flow and gas pressure upstream of the burner.

Gas smell.

Gas leak. Check the entire gas circuit for leaks using soapy water or a gas detector.

Small exit hot water or lack thereof.

Insufficient inlet water pressure. Increase pressure by installing an additional inlet pump. Clogged water filter. Remove and clean the filter on the DHW line. Heat exchanger with partially or completely blocked pipes. Clean the heat exchanger tubes.

Cold radiators in winter.

Set too low temperature heating or the temperature sensor is faulty. Install more high fever heating or replace the temperature sensor. The pump does not work due to contamination. Remove the screw at the front of the pump and turn the spindle.

Hot radiators in summer

Winter heating mode. Set summer mode.

___________________________________________________________________________________________

___________________________________________________________________________________________

Borino, ZhMZ, Siberia, Alpha Calor, Thermotechnik.
Adjustment gas automation Eurosit 630. Replacement of thermocouple and maintenance of the ignition burner.

In the section on the question Boiler neva lux 8224. error 03 is constant.condensate accumulates in the pressure switch tubes. How to fix this problem. given by the author Vladimir the best answer is Need more detailed information about where it is located, outside temperature, fuel (gas or diesel fuel), winter or summer, etc. And condensate from what (water, gas)?
What can be done to prevent condensate from collecting in the pitot tubes? The Neva Lux 8224 boiler turns off every year in January, showing error 03. Of course, I eliminate the condensate and start the boiler until the next accumulation of condensate, but this problem is pretty boring. Help!

Answer from Yotas Shabanov[guru]
1. Check if the tap is completely closed.
make-up.
2. If the make-up valve is closed all the way, then
it is possible that the make-up valve is not tight.
Replace the make-up valve.
3. Check if the secondary heat exchanger is leaking.
4. Also check if the sensor is working properly
pressure and connectors of its contacts.
Another option: opening the plug on the right side
above, in order to enter the combustion chamber
warm air and not
condensation formed in the presostat tubes.


What does error 01 mean, how to troubleshoot the repair of Neva Lux?

Double-circuit gas boilers Neva Lux 8624, 8230, 8224 are wall-mounted apparatus with forced circulation of the heat carrier (water or antifreeze). Repair and maintenance of Neva Lux boilers is carried out according to service instructions by a specialized service organization, which is also engaged in installation, commissioning and service work with the delivery, replacement of faulty parts with new spare parts. heating equipment Neva Lux.

So, with error 01, the flame does not ignite in the combustion chamber or the ignition starts, but it turns out to be unsuccessful - the Neva boiler does not work. Concisely, in this case, one or several reasons for error 01 may be present at the same time. Consider all the causes of the emergency and give a full volume of recommendations for repair gas boiler Neva Lux when error 01 occurs. Technical information presented to service engineers organizations for the repair of gas equipment.

Error 01 in the electronic control board is often found when repairing gas boilers from various manufacturers of electronic heating equipment with electronic control. The first common malfunction, the lack of ignition, is the incorrect operation of the entire chain of volatile and mechanical actions, starting from the pilot and ending with the main one. gas burner... Similar issues at the time of error 01 are related to wall-mounted boilers Visman Vitopend 100, Baksi, Kiturami, Electrolux, Ariston, Immergaz, Neva Lux 8224 and other models from various manufacturers. During an external examination of the gas appliance, it is necessary to make sure that all the manufacturer's recommendations for installing a gas boiler are followed: electricity, electronics, gas, chimney, air flow, correct installation of the Neva Lux boiler according to wiring diagram and the rules of the gas industry.

Repair of the gas boiler Neva Lux with error 01 information begins with checking the gas supply to the heating boiler fittings. Next, we check all RTs for operating condition, observing the contact ability of the relay. Gas modulator valve diagnostics, static and dynamic pressure... By default, the elements of ignition, ionization are subject to inspection and maintenance. In this case, the gaps with respect to the burner section along two electrodes must be observed. Eliminate distortions and mechanical damage interfering correct settings boiler. Diagnostics of the ignition transformer unit (coil), if there is no power to the ignition electrode.

During the repair of the Neva Lux boiler, which runs on liquefied gas, it is necessary to prepare documents for the last refueling of the gas tank (technical data of the fuel), a contract for those. maintenance of the gas boiler and call a service technician for diagnostics and repair of gas. apparatus.

Timely, constant maintenance of gas boilers Neva Lux gives uninterrupted operation of equipment, warmth and comfort in your homes. By carrying out scheduled repairs, the necessary replacement of spare parts, you extend the life of the Neva Lux boilers and make the right investment.

Popular gas equipment- heaters, columns, gas stoves and boilers for more than 50 years have been produced by the Gazoapparat plant located in St. Petersburg. After the creation of the Baltic Gas Company»The enterprise became a part of it, retaining its production capacity and specialization. The current name of the company is Neva. It is developing rapidly and produces high-tech boilers equipped with modern automation. For example, a popular and demanded series - gas boilers Neva Lux, which is presented in two categories.

The range of popular gas boilers manufactured by Neva includes two basic series: Lux and Turbo. In this article, we will consider the most famous and popular Lux series, which is divided into two categories:

The most popular boilers of the Neva Lux series

Modern gas boilers of the luxury class are produced under the Neva brand, in which the shortcomings of previously produced models are eliminated. The design has been changed, modern automation has been installed, but the price of the products is lower than the models of Western companies with similar parameters. With other models of gas boilers domestic production can be found in our article.

Model Neva Lux 8618

For gas boilers Neva Lux, the price depends on the model. Single-circuit models are cheaper, double-circuit models are more expensive. For example, one of the most popular models of this series, the gas boiler NevaLux 8618 is in demand due to its low price and the following qualities and capabilities:

The popular single-circuit gas boiler Neva Lux 8618 for wall installation intended only for heating, but, if necessary, the organization of DHW is possible using a boiler indirect heating... The model has a maximum simple design with non-volatile automation. The price of this boiler is the lowest of the entire model range.

Model Neva Lux 8224

Wall mounted boiler gas Neva Suite 8224 is designed for heating rooms up to 250 m2. The boiler is equipped with a unique water-cooled combustion chamber. High precision temperature setting is provided by a special microprocessor. In terms of their parameters, the boilers of the Neva company are not inferior to foreign samples, the only difference that the gas boiler Neva Lux 8224 has is the price of reviews of many owners confirm this.

This model has two heat exchangers. A plate heat exchanger is used for hot water supply, and a copper heat exchanger built into the Neva Lux gas boiler of this series is used for the heating circuit.

The model can use a PC for diagnostics and configuration, as well as remote control.

On the popular gas boiler Neva Lux 8224, reviews found on the network fully confirm the excellent consumer qualities device. Many reviews emphasize that the price for the Neva Lux 8224 gas boiler is relatively small at high performance... This is a wall-mounted double-circuit model, which is designed for heating rooms up to 240 m2. The unit provides hot water supply (DHW).

Constructive components

From a technical point of view, the wall-mounted gas boiler Neva is flawless. It implements all technical achievements in heating engineering, as well as developments in the field electronic control heating circuits.

Structurally, the gas double-circuit boiler Neva consists of the following interconnected systems:

Advertising on the Internet and on television calls for buying a gas double-circuit wall-mounted boiler Neva Lux, as the most economical, cheapest, convenient, etc. Can you believe these advertisements and reviews on the web pages of online stores?

How to buy a gas boiler and not be mistaken?

A buyer, choosing, for example, a wall-mounted gas boiler Neva Lux 8224 reviews on which may be untrue and written to order, must understand that they cannot be relied upon. Indeed, it often happens that the design is perfect, the equipment is the most modern, but poor-quality assembly impairs all the advantages. For example, in 2014, the Neva Lux 8224 wall-mounted gas boiler is characterized by reviews as a naturally raw product, which is called - modify with a file.

Such a review appeared due to poor-quality assembly, as well as in connection with the unstable operation of the boiler due to a flaw coaxial chimney, which was not specified in the instructions. Of course, at present, the Neva company has taken certain measures and eliminated the shortcomings in the assembly of the product. There are practically no complaints about the Lux 8618 model and you can buy a single-circuit wall-mounted gas boiler Neva Lux, with delivery to any region, in specialized stores.

For mounted gas boilers, prices depend on their power, type, configuration and demand for the device. For example, the Neva Lux double-circuit wall gas boiler offered by many online stores, whose price at a power of 24 kW, but with different configurations, ranges from 31,800 to 35,600 rubles.

The most expensive boiler Nevalux 8224 is equipped with a built-in storage boiler. When choosing a boiler for heating, if you are satisfied with the Neva Lux 8224 gas boiler, the price of reviews is best obtained from real owners or specialists in gas equipment.

Malfunctions of the gas boiler Neva Lux

The simplest single-circuit and non-volatile model Neva Lux 8618. It completely lacks electronics. A simple gas boiler Neva is very reliable.

The most common malfunctions characteristic of this boiler are as follows:

  • very low level gas pressure in the pipeline;
  • low pressure due to the presence of air in the circuit;
  • extinction of the burner flame;
  • mechanical damage to the boiler or heating circuit.

The presence of a control unit with a microprocessor in the Neva Lux 8224 model allows for self-diagnosis of malfunctions that have arisen during the operation of a gas boiler. The electronics that are installed on the gas double-circuit wall-mounted boiler Neva Lux displays malfunctions on the display in the form of an error code.

Display error codes

Any technical device may break. The Neva Lux boiler of any model is no exception. Its stoppage may be due to the failure of any element in the control system or their incorrect operation. The control system displays the error code, and knowledge of the error code makes it easier to detect the malfunction.

The following error codes are displayed:

Error 01. This error indicates unsuccessful ignition. The boiler does not turn on:

Error 02. Overheating of the coolant. The boiler does not work:


Error 03. Lack of traction:


Error 04. Low water pressure in the circuit:


Error 05. Failure of the heating system temperature sensor:


Error 06. Failure of the DHW temperature sensor:

  • sensor malfunction;
  • open or short circuit of the electrical circuit between the sensor and the electronic board.

Other malfunctions that cannot be shown on the display. For example, if there is no electricity, the boiler will not turn on and will not work. Of course, if you establish, then such a nuisance can be avoided.

Fuse blown. A fuse rarely blows for no reason. If, after replacing it with a similar fuse, it blows again, then you need to find the cause. In no case should you install bugs that can damage the entire boiler electronics.

If the electronic board was accidentally flooded with water. You need to turn off the boiler from the network and dry the board warm air from a hair dryer. Sometimes there may be a malfunction of the electronics. To reset to the initial position, press the RESET button. If it does not help, then disconnect the boiler from the network for a few minutes and turn it on again.

If you smell gas, find and repair the leak immediately.

If you cannot fix the leak yourself, it is recommended to call the gas service by emergency number 104.